The table below shows the Conductivity/TDS Equivalents for various Myron L® Standard Solutions.


Application Bulletin

Housing img

POOLMETER™

PoolMeter™ Specifications:

Ranges: 0-5000 ppm Total Dissolved Solids (TDS) "T" 0-5000 ppm Sodium Chloride (NaCl) "N"
Accuracy: ±2% of full scale 

 

±1% at calibration point

Repeatability: ±1%
Temperature

 

Compensation:

Automatic to 25°C/77°F for samples 

 

between 10-71°C/50-160°F

Electrodes (Built-in): Never need replatinizing or replacement 
Cell Cup: Chip and crack resistant polyethylene
Calibration: Built-in standardization "S" value. 

 

Easy and fast with standard solutions.

Circuitry: Sealed against moisture
Power: One 9V battery supplied; 

 

Battery Life: >2000 tests/1 year

Dimensions: 3.4 W x 4.5 D x 4.0 H in./ 

 

86 W x 114 D x 102 H mm

Weight: 1 lb./0,45 kg 

Data Sheet

Housing img

DIALYSATE METERS™ SINGLE & DUAL RANGE

DIALYSATE METERS™ Specifications:

Ranges:  
MODEL D-1 11-15 millimhos
MODEL D-2 0-10 millimhos

 

0-20 millimhos

Accuracy: ± 2% of full scale

 

±1% at calibration point

Repeatability: ±1%
Temperature Compensation: Automatic to 25°C/77°F for samples 10-71°C/50-160°F
Electrodes: Never need replatinizing or replacement
Calibration: Easy and fast with Standard Solutions and finger adjustable internal trimmer
Circuitry: Solid state, sealed against moisture
Power: Two standard 9-volt batteries supplied
Battery Life: Approximately 1 year or 2,000 tests
Case: Heavy gauge, textured ABS
Cell Cup: Chip/crack resistant polyethylene
Dimensions: 3.4 W x 4.5 D x 4.0 H in./ 86 x 114 x 102 mm
Weight: 1 lb./450 grams

Data Sheet

Housing img

RO METERS™

RO Meters™ Technical Specifications:

Ranges:  
RO-1

 

RO-1NC

0-1250 ppm (0-250 blue, 250-500 orange, 500-1250 red)

 

0-1250 ppm (no color band)

Accuracy: ±2% of full scale
Repeatability: ±1%
Temperature Compensation: Automatic (to 25°C/77°F) for samples between 10-71°C/50-160°F
Electrodes (built-in): Never need replatinizing or replacement 
Cell Cup: Chip and crack resistant polyethylene
Recalibration: Internal electronic standard quickly verifies on-site accuracy
Circuitry: Solid-state, sealed against moisture
Power: One 9V battery supplied; Battery Life: >2000 tests/1 year
Dimensions: 3.4 W x 4.5 D x 4.0 H in./ 86 W x 114 D x 102 H mm
Weight: 1 lb./0,45 kg 

Data Sheet

Housing img

AGRI-METERS™

AGRI-METERS™ Specifications:

Conductivity Range: 0-5 millimhos
pH Range: 2-12 pH (AG6/PH only)
Accuracy: pH: ±0.2 pH units
Conductivity: ±2% of full scale
Repeatability: ±1%
Temperature Compensation: Automatic (to 25°C) for Conductivity samples between 50-160°F/10-71°C
Electrodes (Built-in): pH: KCI gel-filled; field replaceable
Conductivity: Never need replatinizing or replacement
Calibration: Easy finger adjustment of pH Zero and Gain (slope) and Conductivity
Circuitry: Solid State sealed against moisture
Power: One 9-volt battery supplied
Battery Life: Approximately one year or 2,000 tests
Case: Heavy gauge textured ABS
Cell Cup: Chip/crack resistant polyethylene
Dimensions: 3.4 W x 4.5 D x 4.0 H in./86 x 114 x 102 mm
Weight: Less than 1 lb./0,45 kg

Data Sheet

Housing img

DS & PDS METERS™

DS/pDS Meters™ Specifications:

Ranges: Conductivity

 

pH

1, 3, 4 or 5 depending on model, 2-12 pH (pDS Meters only)

 

(See meters table)

Readout: 2½ in. taut-band shock resistant meter
Units of Measure* Choice of parts per million (ppm) TDS or micromhos (µM)/microsiemens (µS) conductivity
Accuracy: Conductivity

 

pH

±2% full scale 

 

±0.2 pH units

Repeatability ±1%
Temperature
Compensation
Automatic (to 25°C/77ºF) for conductivity samples between 10-71°C/50-160°F
Calibration

 

Controls

Conductivity 

 

pH Zero and pH Gain

Electrodes (built-in)  Conductivity: Never need replatinizing pH: KCl gel-filled, field replaceable
Cell Cup Chip and crack resistant polyethylene
Circuitry Very stable; requires minimal recalibration
Power One 9 volt battery supplied; 

 

Battery Life: >2000 tests/1 year

Dimensions 3.4 W x 4.5 D x 4.0 H in./ 

 

86 W x 114 D x 102 H mm

Weight 1 lb./0,45 kg

*1 µM (micromho) = 1 µS (microsiemen)

DS Meters™:

Model 512T4* 512M5* 512T5* 512T10* 532M1* 532T1* 532T2* EP-10 EP
Range(s) 0-2500 0-5000 0-5000  0-10,000 0-50

 

0-500

0-5000

0-50

 

0-500

0-5000

0-25

 

0-250

0-2500

0-10

 

0-100

0-1000

0-10000

0-0.5

 

0-5

0-50

0-500

0-5000

Units Measured ppm** µM  ppm ppm**  µM ppm  ppm  µM  µM, MΩ
Recommended
NIST Standard
Solution Key
F G G O B,D,G B,D,G A,C,F K,M,O B,D,G

pDS Meters™:

Model T6/PH* T2/PH* EP11/PH
Range(s) 2-12 pH

 

0-5000 

2-12 pH

 

0-50

0-500

0-5000

2-12 pH

 

0-10

0-100

0-1000

0-10000

Units Measured pH, ppm pH, ppm pH, µM
Recommended
NIST Standard
Solution Key
G B,D,G K,M,O

Data Sheet

Housing img

TECHPRO™ II (TP1, TPH1)

TechPro II™ Specifications:

Display: 4 Digit Liquid Crystal Display
Dimensions: 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in
Weight: 320 g/11.2 oz.
Case/Cell Material: Valox
Cond/TDS Cell Capacity: 5 ml/0.2 oz.
pH Sensor Well Capacity: 1.2 ml/0.04 oz. 
Power: 9V alkaline battery
Battery Life: >100 hours (5000 readings)
Operating/Storage Temperature: 0 – 55°C/32 – 132°F
Protection Ratings: IP67/NEMA 6 WATERPROOF

TechPro II™ Parameters:

Ranges:

Model Conductivity TDS pH TC – 25°C/77°F 
TP1 0 – 9999 µS

 

10 – 20.00 mS 

0 – 9999 ppm

 

10 – 20.00 ppt

—  0 – 71°C 

 

32 – 160°F

TPH1 0 – 9999 µS 

 

10 – 20.00 mS

0 – 9999 ppm

 

10 – 20.00 ppt 

0 – 14  0 – 71°C

 

32 – 160°F 

Accuracy:

Model Conductivity/TDS pH Temperature Reading
TP1 ±1% of reading  —  ±0.1°C/F
TPH1 ±1% of reading  ±0.02 pH ±0.1°C/F

Data Sheet

Housing img

ULTRAPENX2™ PTBT6

ULTRAPEN™ PTBT6 Specifications:

System Requirements: Myron L® Company PTBTX2TM App: Apple iOS 10.0 or later; Android OS 7.0 or later.
Specifications Nitrate as Nitrogen NO3–N Nitrate NO3 Temperature
Ranges 1-1400 ppm 4.4-6200 ppm 0 – 71°C / 32 – 160°F
Accuracy1 ± 10% of the reading ± 10% of the reading ± 0.1°C
Resolution 0.1 ppm 0.1 ppm 0.1°C/F
pH Range: 3-11 pH
Time to Reading Stabilization: 10 – 180 seconds
Power Consumption:  Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Physical Dimensions: 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D
Weight: 54 g or 1.94 oz.
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type: N type, Alkaline 1.5 V
Calibration Standard Solutions: 1, 10, 100, or 1000 ppm NO3–N 
Operating/Storage Temperature: 0-40°C / 32-104°F2
Enclosure Ratings: IP67 and NEMA 6
EN61236-1: 2006 – Annex A: 2008; Electrostatic discharge to case of instrument may cause PTBT6 to spontaneously power ON. In this case, the PTBT6 will power OFF after several seconds.  

Data Sheet

Housing img

ULTRAPENX2™ PTBT5

ULTRAPENx2™ PTBT5 Specifications:

System Requirements: Myron L® Company PTBTX2TM App: Apple iOS 10.0 or later; Android OS 7.0 or later.

 

Specifications DO Concentration DO Saturation Temperature
Ranges 0-20 ppm 0-200% 0 – 71°C / 32 – 160°F
Accuracy1 ± 0.2 ppm or ± 2% of the reading, whichever is greater (up to 40ºC) 0.0% to ≤ 100.0%: ± 20 counts; >100%: ± 2% of the reading. ± 0.1°C
Resolution 0.01 ppm 0.1% 0.1°C/F

 

Altitude Adjustment: -2,000 ft. to 15,000 ft. in increments of 100 ft.
Salinity Adjustment: 0 – 50 ppt in increments of 1 ppt
Time to Reading Stabilization: 10 – 180 seconds
Calibration Methods: 1 or 2 Point; 0 ppm DO Calibration Solution, Air or Water
Operating/Storage Temperature: 0 – 55°C / 32 – 131°F
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Temperature Compensation for Membrane Permeability: Automatic
Physical Dimensions: 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D
Weight: 54 g or 1.94 oz.
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type: N type, Alkaline 1.5 V
Water Resistance: IP67 and NEMA 6
EN61236-1: 2006 – Annex A: 2008; 1999/5/EC Annex III Electrostatic discharge to case of instrument may cause PT5 to spontaneously power ON. In this case, the PT5 will power OFF after several seconds.  
  WARNING! These products can expose you to chemicals including Di(2-ethylhexyl)phthalate (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

1Accuracy after Temperature Controlled, Full Calibration.

ULTRAPENx2™ PTBT5 Measurement Modes:

MODE METHOD OF MEASUREMENT
Hold Displays real-time readings until stable or 3 minutes, whichever comes first, then displays final readings.
LIVE Displays real-time readings continuously for up to 5 minutes.

ULTRAPENx2™ PTBT5 Parameter Modes:

MODE PARAMETER MEASURED
DO Default Display alternates between DO Concentration in ppm, DO Saturation in % and Temperature.
DO Concentration Display alternates between DO Concentration in ppm and Temperature.
DO Saturation Display alternates between DO Saturation in % and Temperature.

Data Sheet

Housing img

ULTRAPENX2™ PTBT4

ULTRAPENx2™ PTBT4 Specifications:

System Requirements: Myron L® Company PTBTX2TM App: Apple iOS 10.0 or later; Android OS 7.0 or later.
FCE ™ Free Chlorine Range: 0 – 10.0 ppm
FCE ™ Free Chlorine Accuracy: < 5.00 ppm: ± 0.3 ppm; ≥ 5.00 ppm: ± 0.5 ppm
FCE ™ Free Chlorine Resolution: 0.01 ppm
Temperature Range: 0 – 71°C / 32 – 160°F
Temperature Accuracy: ± 0.1ºC
Temperature Resolution: 0.1ºC / 0.1ºF
Power Consumption: Active Mode 30-140 mA Sleep Mode 2 µA
Temperature Compensation:  pH: Automatic to 25ºC

 

ORP: Automatic In Calibration Mode From 15ºC to 30ºC

Physical Dimensions:  17,15 cm L x 1,59 cm D or 6.75 in. L x .625 in. D
Weight:  50.4 g / 1.78 oz. (without soaker cap and lanyard)
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type:  One N type, Alkaline, 1.5 V
Calibration Standard Solutions:  PH4, PH7, PH10, ORP80, ORP260, ORP470
Operating/Storage Temperature:  0 – 55ºC / 32 – 131ºF
Enclosure Ratings:  IP67 and NEMA6
EN61236-1: 2006 – Annex A: 2008; Electrostatic discharge to case of instrument may cause PTBT4 to spontaneously power ON. In this case, the PTBT4 will power OFF after several seconds.

Data Sheet

Housing img

ULTRAPENX2™ PTBT3

ULTRAPENx2™ PTBT3 Functions:

MODE METHOD OF MEASUREMENT
Hold Once stabilized, the readings are captured then displayed.
LIVE Real-time readings are displayed continuously during measurement.

ULTRAPENx2™ PTBT3 Specifications:

System Requirements: Myron L® Company PTBTX2™ App: Apple iOS 10.0 or later; Android OS 7.0 or later.
Measurement Range: ORP: -1000 mV to +1000 mV; Temperature: 0 – 71ºC / 32 – 160ºF 
Accuracy: ORP: ± 10 mV; Temperature: ± 0.1ºC
Resolution: ORP: 1 mV; Temperature: 0.1ºC / 0.1ºF
Time to Reading Stabilization: 10 – 45 Seconds
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Temperature Compensation: Automatic In Calibration Mode From 15ºC to 30ºC
Physical Dimensions: 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D
Weight: 50.4 g / 1.78 oz
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type:  One N type, Alkaline 1.5 V
Calibration Standard Solution: ORP80, ORP260, ORP470
Operating/Storage Temperature: 0 – 55ºC / 32 – 131ºF
Water Resistance: IP67 and NEMA 6
EN61236-1: 2006 – Annex A: 2008; Electrostatic discharge to case of instrument may cause PTBT3 to spontaneously power on. In this case, the PTBT3 will power off after several seconds.
FCC ID: T7VPAN17 The Bluetooth transceiver device meets the requirements for modular transmitter

 

approval as detailed in FCC Public Notice DA00-1407.

Canada (IC), license:

 

IC: 216Q-PAN17

The Bluetooth transceiver device meets the requirements for modular transmitter

 

approval as detailed in RSS-GEN.


Data Sheet

Housing img

ULTRAPENX2™ PTBT2

ULTRAPENx2™ PTBT2 Specifications:

System Requirements: Myron L® Company PTBTX2™ App: Apple iOS 10.0 or later; Android OS 7.0 or later
Measurement Range: 0.00 – 14.00 pH; Temperature: 0°-71°C / 32-160°F
Accuracy (After Wet Calibration): ± 0.01 pH; Temperature: ± 0.1ºC
Repeatability: ± 0.01 pH; Temperature: ± 0.1ºC / ± 0.1ºF
Resolution: 0.01 pH; Temperature: 0.1ºC / ºF
Time to Reading Stabilization: 10 – 30 Seconds
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Temperature Compensation: Automatic to 25ºC
Physical Dimensions: 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D
Weight: 54 g or 1.94 oz
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type:  One N type, Alkaline 1.5 V
Calibration Standard Solution: 4.0 pH, 7.0 pH, 10.0 pH
Operating/Storage Temperature: 0 – 55ºC / 32 – 131ºF
Water Resistance: IP67 and NEMA 6
EN61236-1: 2006 – Annex A: 2008;  Electrostatic discharge to case of instrument may cause PTBT2 to spontaneously

 

power on. In this case, the PTBT2 will power off after several seconds

FCC ID: T7VPAN17 The Bluetooth transceiver device meets the requirements for modular transmitter

 

approval as detailed in FCC Public Notice DA00-1407.

Canada (IC), license:

 

IC: 216Q-PAN17

The Bluetooth transceiver device meets the requirements for modular transmitter

 

approval as detailed in RSS-GEN. 


Data Sheet

Housing img

ULTRAPENX2™ PTBT1

ULTRAPENx2™ PTBT1 Specifications:

System Requirements: Myron L® Company PTBTX2™ App: Apple iOS 10.0 or later; Android OS 7.0 or later.
Measurement Range: Conductivity & TDS: 1-9999 µS or ppm; Salinity: 0.0010-9.999 ppt;

 

Temperature: 0°-71°C / 32°-160°F

Accuracy (After Wet Calibration): ± 1% of Reading; Temperature: ± 0.1ºC
Resolution: Conductivity and TDS: 0.1 for 1.0 – 99.9 µS or ppm 

 

1 for 100 – 9,999 µS or ppm

Salinity: 0.0001 for 0.0010 – 0.0999 ppt

 0.001 for 0.100 – 9.999 ppt

Temperature: 0.1ºC orºF 

Repeatability: <1000 µS or ppm ± 1 Count

 

≥ 1000 µS or ppm ± 0.3% of Reading 

Time to Reading Stabilization: 10 – 20 seconds
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Temperature Compensation Method: Automatic to 25ºC
Physical Dimensions: 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D 
Weight: 55 g or 1.94 oz.
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type: One N type, Alkaline 1.5 V
Calibration Standard Solution: KCl: 1800 µS for COND; 442™: 3000 ppm (2027 ppm NaCl) for TDS and Salinity
Operating/Storage Temperature: 0 – 55ºC or 32 – 131ºF
Water Resistance: IP67 and NEMA 6
EN61236-1: 2006 – Annex A: 2008;  Electrostatic discharge to the PTBT1 may cause it to spontaneously power on.

 

If this occurs, the PTBT1 will power off after several seconds.

FCC ID: T7VPAN17 The Bluetooth transceiver device meets the requirements for modular transmitter

 

approval as detailed in FCC Public Notice DA00-1407.

Canada (IC), license:

 

IC: 216Q-PAN17

The Bluetooth transceiver device meets the requirements for modular transmitter

 

approval as detailed in RSS-GEN. 

ULTRAPENx2™ PTBT1 Functions:

MODE PARAMETER SOLUTION MODEL UNITS
Cond KCl  Conductivity potassium chloride microsiemens (µS)
TDS 442 Total Dissolved Solids (TDS) Myron L® Company, 442 Natural Water™ Standard Solution parts per million (ppm)
TDS NaCl Total Dissolved Solids (TDS) sodium chloride parts per million (ppm)
SAL 442 Salinity (SAL) Myron L® Company, 442 Natural Water™ Standard Solution parts per thousand (ppt)
SAL NaCl Salinity (SAL) sodium chloride parts per thousand (ppt)

Data Sheet

Housing img

ULTRAPEN™ PT6

ULTRAPEN™ PT6 Measurement Modes:

MODE METHOD OF MEASUREMENT
Hold Displays real-time readings until the LED turns solid ON, then displays final readings.
LIVE Displays real-time readings continuously for up to 5 minutes.

ULTRAPEN™ PT6 Parameter Modes:

MODE PARAMETER MEASURED
N Display alternates between Nitrate as Nitrogen (NO3—N), and Temperature
NO3 Display alternates between Nitrate (NO3—), and Temperature
mV Display alternates between millivolt (mV), and Temperature

ULTRAPEN™ PT6 Specifications:

Specifications Nitrate as Nitrogen NO3—N Nitrate NO3— Temperature
Ranges 1-1400 ppm 4.4-6200 ppm 0 – 71°C / 32 – 160°F
Accuracy1 ± 10% of the reading ± 10% of the reading ± 0.1°C
Resolution 0.1 ppm 0.1 ppm 0.1°C/F
pH Range: 3-11 pH
Time to Reading Stabilization: 10 – 180 seconds
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 μA
Physical Dimensions: 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D
Weight: 54 g or 1.94 oz.
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type: N type, Alkaline 1.5 V
Calibration Standard Solutions: 1, 10, 100, or 1000 ppm NO3—N
Operating/Storage Temperature: 0-40°C / 32-104°F2
Enclosure Ratings: IP67 and NEMA 6
EN61236-1: 2006 – Annex A: 2008; Electrostatic discharge to case of instrument may cause PT6 to spontaneously power ON. In this case, the PT6 will power OFF after several seconds.

Data Sheet

Housing img

ULTRAPEN™ PT5

ULTRAPEN™ PT5 Measurement Modes:

MODE METHOD OF MEASUREMENT
Hold Displays real-time readings until stable or 3 minutes, whichever comes first, then displays final readings.
LIVE Displays real-time readings continuously for up to 5 minutes.

ULTRAPEN™ PT5 Parameter Modes:

MODE PARAMETER MEASURED
DO Default Display alternates between DO Concentration in ppm, DO Saturation in % and Temperature.
DO Concentration Display alternates between DO Concentration in ppm and Temperature.
DO Saturation Display alternates between DO Saturation in % and Temperature.

ULTRAPEN™ PT5 Specifications:

Specifications DO Concentration DO Saturation Temperature
Ranges 0-20 ppm 0-200% 0 – 71°C / 32 – 160°F
Accuracy1 ± 0.2 ppm or ± 2% of the reading, whichever is greater (up to 40ºC) 0.0% to ≤ 100.0%: ± 20 counts; >100%: ± 2% of the reading. ± 0.1°C
Resolution 0.01 ppm 0.1% 0.1°C/F
Altitude Adjustment: -2,000 ft. to 15,000 ft. in increments of 100 ft.
Salinity Adjustment: 0 – 50 ppt in increments of 1 ppt
Time to Reading Stabilization: 10 – 180 seconds
Calibration Methods: 1 or 2 Point; 0 ppm DO Calibration Solution, Air or Water
Operating/Storage Temperature: 0 – 55°C / 32 – 131°F
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Temperature Compensation for Membrane Permeability: Automatic
Physical Dimensions: 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D
Weight: 54 g or 1.94 oz.
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type: N type, Alkaline 1.5 V
Water Resistance: IP67 and NEMA 6
EN61236-1: 2006 – Annex A: 2008; 1999/5/EC Annex III  Electrostatic discharge to case of instrument may cause PT5 to spontaneously power ON. In this case, the PT5 will power OFF after several seconds.

Data Sheet

Housing img

ULTRAPEN™ PT4

ULTRAPEN™ PT4 Measurement Modes:

MODE METHOD OF MEASUREMENT
Hold (default) Once stabilized, the readings are captured then displayed.
LIVE Real-time readings are displayed continuously during measurement.

ULTRAPEN™ PT4 Specifications:

FCE ™ Free Chlorine Range: 0 – 10.0 ppm
FCE ™ Free Chlorine Accuracy: < 5.00 ppm: ± 0.3 ppm, ≥ 5.00 ppm: ± 0.5 ppm
FCE ™ Free Chlorine Resolution: 0.01 ppm
Temperature Range: 0 – 71°C / 32 – 160°F
Temperature Accuracy: ± 0.1ºC
Temperature Resolution: 0.1ºC / 0.1ºF
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Temperature Compensation:  pH : Automatic to 25°C ORP: Automatic in Calibration Mode from 15ºC to 30ºC
Physical Dimensions:  17.15 cm L x 1,59 cm D or 6.75 in. L x .625 in. D
Weight:  50.4 g / 1.78 oz. (without soaker cap and lanyard)
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type:  One N type, Alkaline, 1.5 V
Calibration Standard Solutions:  PH4, PH7, PH10, ORP80, ORP260, ORP470
Operating/Storage Temperature:  0 – 55ºC / 32 – 131ºF
Enclosure Ratings:  IP67 and NEMA6
EN61236-1: 2006 – Annex A: 2008:  Electrostatic discharge to the PT4 may cause it to spontaneously turn on. If this occurs, the PT4 will turn off.

Data Sheet

Housing img

ULTRAPEN™ PT3

ULTRAPEN™ PT3 Functions:

MODE METHOD OF MEASUREMENT
Hold (default) Once stabilized, the readings are captured then displayed.
LIVE Real-time readings are displayed continuously during measurement.

* Temperature compensation in calibration mode: Temperature affects the reaction potentials for all chemicals differently. True ORP is the direct measurement of electron activity during an oxidation-reduction reaction, regardless of temperature. However, for maximum accuracy and ease of calibration, the Myron L® Company has developed three calibration standard solutions with known dissolved species. We derived the temperature compensation (from 15ºC to 30ºC) for those solutions, and embedded automatic temperature compensation into the calibration function of your PT3. Note: To verify calibration while in measurement mode, you must manually correct for any variation in temperature. Example: @25ºC, ORP2602OZ calibration solution will read 260mV, however @ 20.0ºC ORP2602OZ will read 265mV.

ULTRAPEN™ PT3 Specifications:

ORP Range: -1000 mV to +1000 mV
ORP Accuracy: ± 10 mV
ORP Resolution: 1 mV ORP
Temperature Range: 0 – 71°C / 32 – 160°F
Temperature Accuracy: ± 0.1ºC
Temperature Resolution: 0.1ºC / 0.1ºF
Time to Reading Stabilization:  10 – 45 seconds
Power Consumption: Active Mode: 30 – 140 mA, Sleep Mode: 2 µA
Temperature Compensation:  Automatic In Calibration Mode From 15ºC to 30ºC
Physical Dimensions:  17.15 cm L x 1.59 cm D or 6.75 in. L x 0.625 in. D
Weight:  50.4 g / 1.78 oz. (without soaker cap and lanyard)
Case Material: Anodized Aircraft Aluminum with Protective Coating
Battery Type:  One N type, Alkaline, 1.5 V
Calibration Standard Solutions:  ORP80, ORP260, ORP470
Operating/Storage Temperature:  0 – 55ºC / 32 – 131ºF
Enclosure Ratings:  IP67 and NEMA6
EN61236-1: 2006 – Annex A: 2008:  Electrostatic discharge to the PT3 may cause it to spontaneously turn on. If this occurs, the PT3 will turn off.

Data Sheet

Housing img

POOLPRO™ PS6FCᴱ & PS9TKB

POOLPRO™ Specifications:

Display: 4 Digit Liquid Crystal Display
Dimensions: LxWxH 196 x 68 x 64 mm/ 7.7 x 2.7 x 2.5 in.
Weight: 352 g/12.4 oz.
Case/conductivity cell material: VALOX™
Cell capacities (w/o cell extender): pH/ORP: 1,2 mL/0.04 oz. Cond/TDS/MIN/SALT: 5 mL/0.2 oz.
Power: 9V alkaline battery
Battery life: >100 hours (5000 readings)
Operating/storage temperature: 0 – 55°C/32 – 132°F
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet)
EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232
*™SABIC INNOVATIVE PLASTICS IP BV

Functional Specifications:

Conductivity Ranges: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges
  Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1(<10 mS); 0.01(<100 mS); 0.1(<200 mS)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
  Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
TDS Ranges: 0–9999 ppm; 10–200 ppt; in 5 autoranges
  Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
  Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
Mineral/Salt Ranges: 0–200 ppt; in 5 autoranges
  Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
  Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
pH Ranges: 0–14 pH
  Resolution: 0.01 pH
  Accuracy**: ±0.01 pH
  Auto Temperature Compensation: 0–71°C / 32–160°F
ORP Ranges: ±999 mV
  Resolution: 1 mV
  Accuracy**: ±1 mV
Free Chlorine FCE™ Ranges: 0.00–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9
  Resolution: 0.01 ppm
  Accuracy**: <1.00ppm ±0.3ppm and ≥1.00ppm ±0.2ppm
  Auto Temperature Compensation: 0–71°C / 32–160°F
Alkalinity Titration Ranges: 10-800 ppm
  Resolution: 0.1 ppm
Hardness Titration Ranges: 0-1710 ppm / 0-100 grains
  Resolution: 0.1(<1000 ppm); 1(<1710 ppm); 0.1(<100 grains)
LSI Calculator Ranges: -10 to +10
  Resolution: 0.01
Temperature Ranges: 0–71°C / 32–160°F
  Resolution: 0.1°C/F
  Accuracy: ±0.1°C
*442 Natural Water Standard™ Myron L® Company
**EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
        ± 0.2 pH in the presence or RF fields ≥ 3 V/m.
        ± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).

Data Sheet

Housing img

DIGITAL DIALYSATE METER™ D-4 & D-6

General Specifications:

Display: 4 Digit LCD
Dimensions (LxWxH): 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in.
Weight: 352 g/12.4 oz.
Case Material: VALOX®*
Cond/Res/TDS Cell Material: VALOX®*
Cond/TDS Electrodes (4): 316 Stainless Steel
Cond/Res/TDS Cell Capacity: 5 ml/0.2 oz.
pH/ORP Sensor Well Capacity: 1,2 ml/0.04 oz. (D-6)
Power: 9V Alkaline Battery
Battery Life: >100 Hours/5000 Readings
Operating/Storage Temperature: 0-55°C/32-131°F
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet)
Chemical Resistance: Resistant to hydrocarbons, dilute acids and bases, detergents, and aqueous salt solutions
EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232
Flammability: PCB: UL94, V.0; Case: HB/1.47 or better
* ® Sabic Innovative Plastics

Functional Specifications:

Conductivity Range: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges
  Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1.0(<10 mS); 0.01(<100 mS); 0.1(<200 mS)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
  Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
TDS Range: 0–9999 ppm; 10–200 ppt; in 5 autoranges
  Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1.0(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
  Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
Resistivity Range: 10KΩ–30MΩ
  Resolution: 0.01(<100 KΩ); 0.1(<1000 KΩ); 0.1(>1 MΩ)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
pH (D-6) Range: 0–14 pH
  Resolution: 0.01 pH
  Accuracy**: ±0.01 pH
  Auto Temperature Compensation: 0–71°C / 32–160°F
ORP (D-6) Range: ±999 mV
  Resolution: 1mV
  Accuracy**: ±1 mV
Free Chlorine FCE™ (D-6) Range: 0.2–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9
  Resolution: 0.01ppm
  Accuracy**: <1.00 ppm ±0.3 ppm; ≥1.00 ppm ±0.2 ppm
Temperature Range: 0–71°C / 32–160°F
  Resolution: 0.1°C/F
  Accuracy: ±0.1°C
*442 Natural Water Standard™ Myron L® Company
**EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
        ± 0.2 pH in the presence or RF fields ≥ 3 V/m.
        ± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).

Data Sheet

Housing img

ULTRAMETER™ III 9PTKB

ULTRAMETER III 9P™ Hard Carry Case Kit
Display: 4 Digit LCD Outer Material: ABS plastic
Dimensions (LxWxH): 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in. Inner Material: Foam
Weight: 352 g/12.4 oz. Dimensions: L x W x D: 13.6 x 10 x 5.4 in./346 x 254 x 137 mm
Case/Cell Material: VALOX®* * ® Sabic Innovative Plastics IP BV
Cell Capacities (w/o cell extender): pH/ORP 1,2 mL/0.04 oz. 

 

Cond/TDS/Res: 5 mL/0.2 oz.

 
Power: 9v Alkaline Battery  
Battery Life: 100 Hours/5000 Readings  
Operating/Storage Temperature: 0-55°C/32-132°F  
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet)  
EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232

Functional Specifications:

Conductivity Ranges: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges
  Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1(<10 mS); 0.01(<100 mS); 0.1(<200 mS)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
  Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
  Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
  Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99
TDS Ranges: 0–9999 ppm; 10–200 ppt; in 5 autoranges
  Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
  Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
  Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
  Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99
Resistivity Ranges: 10 KΩ–30 MΩ
  Resolution: 0.01(<100 KΩ); 0.1(<1000 KΩ); 0.1(>1 MΩ)
  Accuracy: ±1% of reading
  Auto Temperature Compensation: 0–71°C / 32–160°F
  Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
pH Ranges: 0–14 pH
  Resolution: 0.01 pH
  Accuracy**: ±0.01 pH
  Auto Temperature Compensation: 0–71°C / 32–160°F
ORP Ranges: ±999 mV
  Resolution: 1 mV
  Accuracy**: ±1 mV
Free Chlorine FCE™ Ranges: 0.00–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9
  Resolution: 0.01 ppm
  Accuracy**: <1.00ppm ±0.3ppm and ≥1.00ppm ±0.2ppm
  Auto Temperature Compensation: 0–71°C / 32–160°F
Alkalinity Titration Ranges: 10-800 ppm
  Resolution: 0.1 ppm
Hardness Titration Ranges: 0-1710 ppm / 0-100 grains
  Resolution: 0.1(<1000 ppm); 1(<1710 ppm); 0.1(<100 grains)
LSI Calculator Ranges: -10 to +10
  Resolution: 0.01
Temperature Ranges: 0–71°C / 32–160°F
  Resolution: 0.1°C/F
  Accuracy: ±0.1°C
*442 Natural Water Standard™ Myron L® Company
**EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
        ± 0.2 pH in the presence or RF fields ≥ 3 V/m.
        ± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).

Data Sheet

Housing img

CONTROLSTIK II™ SYSTEM

Engineering Specifications:

Rinse water usage shall be minimized by means of automatic conductivity control systems. They shall consist of a temperature compensated conductivity sensor, corrosion resistant one-inch solenoid valve, and transformer box which safely reduces line power to the sensor. Enclosure shall be fiberglass with heavy rubber gasket and 316 stainless steel. Circuitry shall be solid-state, and unaffected by changes in voltage. Setpoint adjustment shall be on sensor to minimize tampering. Rinse tank controls shall be Myron L Model 597 or approved equal.

 

Transformer Box Specifications:

Input Power Choice of 110 or 220 VAC, 50/60 Hz;
  Automatic voltage regulation insures operation of the systems from 105-125V or 210-250V respectively.
Output 24 volts @ 600 mA AC
Maximum Power Consumption @ 117V: 12 watts (103 milliamps)
Enclosure IP65/NEMA 4X fiberglass case with heavy gasket and 316 stainless steel hardware.
Lights LEDs indicate POWER (red) and VALVE (yellow)
Electrical Installation Either HARDWIRE with 5/8 in. conduit; or PLUG-IN with 8 ft./2,4 meter, 18 ga. 3-conductor plug.
  (supplied with 110V systems only)
Mounting Flange on enclosure for easy wall mounting
Dimensions 184 H x 197 W x 127 D mm/ 7.25 H x 7.75 W x 5 D in.

 

Sensor Specifications:

Ranges 5-500 micromhos (for high quality water)
  500-5000 micromhos (for normal tap water)
Power 1 volt AC (from transformer box)
On-Off Span Approximately 5% of setpoint
Temperature Compensation Automatic to 25°C/77°F up to 82°C/180°F
Materials Epoxy and 316 stainless steel
Cable 10 ft./3 meter 22 ga., 4-conductor, vinyl jacketed
Installation Corrosion-proof ABS bracket supplied
Dimensions 304 L x 25 Dia. mm/12 L x 1 Dia. in.

 

Solenoid Valve Specifications:

Size 1 in. NPT normally closed; compatible with plastic or metal piping
Power 24 volts @ 200 mA AC
  (from transformer box)
Materials Body: glass reinforced nylon
  Diaphragm: nylon reinforced BUNA N synthetic rubber
  All exposed metal: stainless steel
Operating Pressure 10-100 psi / 0,69-6,90 bar
Miscellaneous adjustable flow control
  manual override
  anti-hammer closing
  conduit connector

Data Sheet

Housing img

720 SERIES II PH / ORP MONITOR / CONTROLLERS

720 Series II Sensor Specifications:

  • Temperature Compensation: Integral temperature sensor provides automatic TC to 25°C between 0 – 100°C/ 32 – 212°F.
  • Pressure/Temperature Limits: P72S: Intermittent use up to 50 psi/690 kPa 100°C/212°F. High Temperature models available, see pH/ORP Sensor Selection Guide.
  • Cable: 5 wire, 24 ga. shielded, 10 ft./3 meters standard. 25 and 100 ft./8 and 30 meter lengths available.
  • Material: 1/2″ MNPT: CPVC body. 3/4″ MNPT: Ryton®* body.
  • Dimensions: P72S typical: overall length 165 mm/6.5 in., body 127 mm/5 in., electrode length 19 mm/.75 in.
  • *Ryton® PPS is a registered trademark of Chevron Phillips Chemical Company LLC

 

Functional Specifications:

Ranges 0-14 pH or ±2000 mV ORP
Display Analog Models: 2.5 in./63 mm meter
  Digital Models: .5 in./13 mm 3½ Digit LCD
  Digital Option: 3½ Digit Backlit
Linearity Electronics: ±0.05% (±0.01 pH units/±1 mV of full scale)
Resolution Analog Meter: ±0.13 pH units/±40 mV
  Digital Display: ±0.01 pH units/±1 mV
Sensitivity 0.05% of full scale (0.01 pH units/1.0 mV)
Stability ±0.05% of full scale (±0.01 pH units/±1.0 mV)
Repeatability ±0.05% of full scale (±0.01 pH units/±1.0 mV)
Calibration Check Built-in (7 and 0 pH / 0 and -2000 mV)
Recorder Output Isolated 0-10 VDC @ 5 mA max. (linear); standard all models 100Ω
Output Impedance 100Ω ±5%
Sensor Inputs 1; 3 input option available.
  (pH & ORP sensors may NOT be mixed.)
Control Function Single Alarm/controller fully adjustable 0-100% of full scale
  Hysteresis: Adjustable from 0.3-3% of full scale
  Indicators: Above (red) and below (green) set point LEDs (reversible)
  Contact Rating: SPDT 10 amp @ 125 VAC, 30 VDC
  Relay operates increasing or decreasing reading (selectable)
  Second Alarm/controller, with above specifications – optional
Solid State Output Powered; 24 VDC unregulated 30 mA max.
Power 115/230 VAC, 50/60 Hz, ±15% (user selectable)
  24 VAC optional
Maximum Power Consumption @ 115V: 100 milliamps
Dimensions 152 H x 122 W x 96 D mm / 6 H x 4.8 W x 3.8 D in.
Construction Fully gasketed, heavy-duty ABS case; water resistant and corrosion proof IP65/NEMA 4X rated
Ambient Temp Range 0-60°C / 32-140°F
Weight 0,9 kg/2 lbs.

Data Sheet

Housing img

750 SERIES II RESISTIVITY MONITOR / CONTROLLERS

750 Series II Resistivity Sensor Specifications:

  • Constant: 0.05
  • Temperature Compensation:  Two integral temperature sensors provide automatic TC to 25ºC.
  • Pressure/Temp Limits:  100 psi/690 kPa @ 212ºF/100ºC.
  • Bushing: Modular Polypropylene threaded 3/4" NPT. 1/2" PVDF or 316 stainless steel fittings (optional).
  • Cable:  Shielded 10 ft./3 meters standard; 25 and 100 ft./ 8 and 30 meter lengths available.
  • Dimensions: Metal portion 30 L x 13 Dia. mm/ 1.2 L x .5 Dia. in.; overall length 91 mm/3.6 in.

Resistivity Sensor — CS10

All 750 Series II Resistivity models require a CS10 series sensor. This reliable sensor features two integral thermistors to ensure accurate and rapid automatic temperature compensation. The sturdy polypropylene standard bushing is modular for easy, inexpensive replacement. A PVDF or 316 stainless steel bushing can also be ordered. The metal portion is available in either 316 stainless steel (standard) or titanium.

Ranges 7 ranges from 0-200K to 0-20MΩ
  See Price List for further details.
Display Analog Models: 2.5 in./63 mm meter
  Digital Models: .5 in./13 mm 3½ Digit LCD
  Digital Option: 3½ Digit Backlit
Accuracy Analog Models: ± 2% of full scale
  Digital Models: ± 1% of full scale
Sensitivity 0.05% of full scale
Stability 0.05% of full scale
Repeatability 0.1% of full scale
Calibration Check Built-in
Recorder Output 0-10 VDC @ 5 mA max. (linear); standard all models
Sensor Inputs 1 (3 input option available)
Control Function Single Alarm/controller fully adjustable 0-100% of full scale
  Hysteresis: Adjustable from 0.3-3% of full scale
  Indicators: Above (green) and below (red) setpoint LEDs (reversible)
  Contact Rating: SPDT 10 amp @ 250 VAC, 30 VDC. Relay operates decreasing or increasing reading (selectable).
  Second Alarm/controller, with above specifications – optional
Solid State Output Powered; 24 VDC unregulated 30 mA max.
Power 115/230 VAC, 50/60 Hz, ±15% (user selectable)
  24 VAC optional
Maximum Power Consumption @ 115V: 100 milliamps
Dimensions 152 H x 122 W x 96 D mm / 6 H x 4.8 W x 3.8 D in.
Construction Fully gasketed heavy-duty ABS case; water resistant and corrosion proof IP65/NEMA 4X rated
Ambient Temp Range 0-60°C / 32-140°F
Weight 0,9 kg/2 lbs.

Data Sheet

Housing img

750 SERIES II CONDUCTIVITY / TDS MONITOR / CONTROLLERS

50 Series II Sensor Specifications:

  • Temperature Compensation: Integral thermistors provide automatic TC to 25ºC between 0-100ºC/32-212ºF.
  • Pressure /Temperature Limits: CS51: 100 psi / 690 kPa @ 100°C/212°F. 250 psig @ 205°C, Models CS40 and CS41 sensors available on special order.
  • Bushing: Modular Polypropylene threaded 3/4" NPT. 1/2" PVDF or 316 stainless steel fittings available as option.
  • Cable: Shielded 10 ft./3 meters standard 25 and 100 ft./ 8 and 30 meter lengths available. 100 ft./30 meter is maximum recommended.
  • Dimensions: CS51: Metal portion 30 L x 13 Dia. mm/ 1.2 L x .5 Dia. in.

Sensors — CS51LC, CS51 and CS52

These reliable sensors feature an integral temperature sensor to ensure accurate and rapid automatic temperature compensation. The sturdy polypropylene bushing is modular for easy inexpensive replacement. Several alternatives for the metal portion of the sensor are available, depending on the demands of the application.

  • CS51LC sensors (0.1 constant) are used for 5 and below.
  • CS51 sensors (1.0 constant) are used between 0-10 and 0-20,000.
  • CS52 sensors (10.0 constant) are used above 20,000.
  • Low cost, low temperature, low pressure sensors available upon request. See 750II Sensor Selection Guide.
Ranges 34 ranges from 0-1 ppm/μS (μM) to 0-200 ppt/mS (mM)
  See Price List for further details.
Display Analog Models: 2.5 in./63 mm meter
  Digital Models: .5 in./13 mm 3½ Digit LCD
  Digital Option: 3½ or 4½ Digit Backlit
Accuracy Analog Models: ± 2% of full scale
  Digital Models: ± 1% of full scale
Sensitivity 0.05% of full scale
Stability 0.05% of full scale
Repeatability 0.1% of full scale
Calibration Check Built-in
Recorder Output 0-10 VDC @ 5 mA max. (linear); standard all models
Sensor Inputs 1 (3 input option available)
Control Function Single Alarm/controller fully adjustable 0-100% of full scale
  Hysteresis: Adjustable from 0.3-3% of full scale
  Indicators: Above (red) and below (green) setpoint LEDs (reversible)
  Contact Rating: SPDT 10 amp @ 250 VAC, 30 VDC. Relay operates decreasing or increasing reading (selectable).
  Second Alarm/controller, with above specifications – optional
Solid State Output Powered; 24 VDC unregulated 30 mA max.
Power 115/230 VAC, 50/60 Hz, ±15% (user selectable)
  24 VAC optional
Maximum Power Consumption @ 115V: 100 milliamps
Dimensions 152 H x 122 W x 96 D mm / 6 H x 4.8 W x 3.8 D in.
Construction Fully gasketed heavy-duty ABS case; water resistant and corrosion proof IP65/NEMA 4X rated
Ambient Temp Range 0-60°C / 32-140°F
Weight 0,9 kg/2 lbs.

Data Sheet

Housing img

ULTRAPEN PH / TEMPERATURE METER

Item Part: PH-MYRON PT2
Handheld meter with pocket clip
Measures 2 parameters:

  • pH (0.00-14.00)
  • Temperature (0–71 °C)
  • Accuracy: ±0.01 pH

1, 2, 3 point calibration
Automatic temperature compensation
Waterproof
Power: N Type Battery (1), included
Dimension: 6.75” L x 0.625” D


DATA SHEET

Housing img

MYRON 6PFC E ULTRAMETER II

Item Part: MYRON 6PIIFC
Measures 6 parameters on field:

  • Conductivity
  • Resistivity (10 KΩ–30 MΩ)
  • TDS
  • ORP (±999 mV)
  • Free Chlorine (0.00–9.99 ppm)
  • pH (0–14)
  • Temperature (0–71 °C)

ORP mV to ppm free chlorine conversion pH/ORP Sensor protective cap
Four-digit display for full 9999 readings, with autoranging capability up to 200 mS/200 ppt
Memory for 100 readings with Date & Time Stamp
capable of wireless data transfer with bluDock™ option installed
Automatic temperature compensation
Auto shut-off
Waterproof
Power: 9 V battery (1)
Dimensions: 7.7” x 2.7” x 2.5”


DATA SHEET

Housing img

MYRON 4PII ULTRAMETER

Item Part: MYRON 4PII
Measures 4 parameters on field:

  • Conductivity
  • Resistivity (10 KΩ–30 MΩ)
  • TDS
  • pH (0–14)
  • Temperature (0–71 °C)
  • Four-digit display for full 9999 readings, with autoranging capability up to 200 mS/200 ppt

Memory for 100 readings with Date & Time Stamp
Capable of wireless data transfer with bluDock™ option installed
Automatic temperature compensation
Auto shut-off
Waterproof
Power: 9 V battery (1)
Dimensions: 7.7” x 2.7” x 2.5”


DATA SHEET

CONTROLLERS

Housing img

900 SERIES MULTI-PARAMETER MONITOR/CONTROLLER™

Outputs

4-20mA / 0-20mA Output
(Model 900M-3C only)

0-10V Recorder Output
The 900 Series 0-10V Recorder Output can be programmed to output 0-10 or 0-5 VDC and export signals from any input channel or derived value.

Relays and Alarms
The relays and alarms operate independently but may be programmed to work in conjunction. Relays and alarms may be set to trigger on measurement values rising above, falling below, In Window (within an upper and lower range of values), or Out Window (outside an upper and lower range of values) for any of the input channels or for derived % rejection.

RS-485 Output
(Model 900M-3C only)

The 900 Series features an RS-485 Serial Communications Output that streams measured and derived data in ASCII format.

PERCENT (%) REJECTION
The Percent Rejection measurement feature compares feed water to the permeate (product) water to determine the percent of dissolved solids removed or rejected by a filtration system thereby quantifying the effectiveness of water filtration systems.

  Conductivity TDS Resistivity Salinity pH ORP/mV IN Temperature
Ranges 0 µS – 200 mS 0 ppm – 200 ppt 10 KΩ – 40 MΩ 0 ppm – 200 ppt 0 – 14 pH ±2000 mV 0 – 250˚C
Accuracy ± 1% of reading ± 1% of reading ± 1% of reading ± 1% of reading ± 0.01 pH ± 2 mV ± 0.1˚C
Resolution 0.01 (<100 µS)

 

0.1 (<1000 µS)

1 (<10,000 µS)

0.01 (<100 mS)

0.1 (≤200 mS)

0.01 (<100 ppm)

 

0.1 (<1000 ppm)

1 (<10,000 ppm)

0.01 (<100 ppt)

0.1 (≤200 ppt)

0.01 (<100 kΩ)

 

0.1 (<1000 kΩ)

0.01 (<10 MΩ)

0.1 (≤40 MΩ)

0.001 (<10 ppt)

 

0.01 (<100 ppt)

0.1 (≤200 ppt)

0.01 pH 1 mV 0.1˚C/F
Auto

 

Temperature

Compensation

0-71˚C

 

32-160˚F

0-71˚C

 

32-160˚F

0-71˚C

 

32-160˚F

0-71˚C

 

32-160˚F

0-71˚C

 

32-160˚F

Adjustable Temperature

 

Compensation

0 – 10%/˚C 0 – 10%/˚C 0 – 10%/˚C 0 – 10%/˚C On/Off
Cond/TDS

 

Ratios

Preprogrammed

KCl, NaCl, 442™ KCl, NaCl, 442™ KCl, NaCl, 442™
Adjustable

 

Cond/TDS

Ratio Factor

0.20-7.99 0.20-7.99 0.20-7.99

900 Series Multi-Parameter Monitor/Controller Data Sheet

Housing img

TDS CONTROLLER

Item Part: TDS-IL
Conductivity Meter for in-line monitoring
Includes TDS sensor with 5 m cable
Features:

  • 4-20 mA signal output
  • Temperature measurement
  • Can switch µS/cm – ppm
  • Auto range conversion
  • Back-light LCD display
  • Conductivity Range: 0-19.99 µS/cm, 0-199.9 µS/cm and 0-1999 µS/cm

Temperature range: 0-50 ℃
Accuracy: 1.5% (FS)
Stability: ± 1.5*10 -3 /24 h
Automatic temperature compensation
Dimensions: 1.9” x 3.8” x 3.9” (HxWxD)
Hole size of meter on panel: 1.8” x 3.6”
Power: 110 V or 220 V, 50 Hz

Housing img

PH CONTROLLER

Item Part: PH- CONT
Suitable for in-line monitoring of pH
Electrode included (5 m cable)
Back-light LCD display
High limit and low limit control
Automatically identifies pH buffer and three-point calibration
Measuring Range: 0-14
Resolution: 0.01
Accuracy: 0.05
Automatic temperature compensation 0-99 ⁰C
Stability: ≤ 0.05/24 h
Measuring distance: ≤ 20 m
Communication: RS485 output
4~20 mA current output
Dimensions: 3.8” x 3.8” x 5.1” (HxWxD)
Hole size on panel: 3.6” x 3.6”
Power: 110 V or 220 V, 50 Hz

Housing img

ORP CONTROLLER

Item Part: ORP
Suitable for in-line monitoring of oxidation-reduction potential
Sensor Included (5 m cable)
Back-light LCD display
High limit and low limit control
Measuring Range: -1999 mV ~ +1999 mV
Resolution: ± 1 mV
Accuracy: ± 2 mV
Automatic temperature compensation 0-99⁰C
Stability: ≤ 2 mV/24h
Measuring distance: ≤ 20 m
Communication: RS485 output
4~20 mA current output
Dimensions: 3.8” x 3.8” x 5.1” (HxWxD)
Hole size on panel: 3.6” x 3.6”
Power: 110 V or 220 V, 50 Hz

Housing img

RO CONTROLLER

Item Part: CONTR-M
RO controller with conductivity meter
Shows operation status of a reverse osmosis system through flow diagram
Combine PLC functions with TDS meter
Ready to be used with level control switch on storage tank
External lockout input
Remote operation capable
Programmable auto fast-flush cycle
TDS sensor with automatic temperature
compensation included (5 m cable)
Process controlled:

  • Low inlet flow
  • Low inlet pressure
  • Inlet valve
  • High pressure pump
  • High conductivity level
  • High level of water on tank
  • Flush valve
  • Measuring range: 0~200 µS/cm

Dimensions: 3.8” x 3.8” x 5.1” (HxWxD)
Hole size on panel: 3.6” x 3.6”
Power: 110 V or 220 V, 50 Hz

MONITORS

Housing img

900 SERIES MULTI-PARAMETER MONITOR/CONTROLLER™

Outputs

4-20mA / 0-20mA Output
(Model 900M-3C only)

0-10V Recorder Output
The 900 Series 0-10V Recorder Output can be programmed to output 0-10 or 0-5 VDC and export signals from any input channel or derived value.

Relays and Alarms
The relays and alarms operate independently but may be programmed to work in conjunction. Relays and alarms may be set to trigger on measurement values rising above, falling below, In Window (within an upper and lower range of values), or Out Window (outside an upper and lower range of values) for any of the input channels or for derived % rejection.

RS-485 Output
(Model 900M-3C only)

The 900 Series features an RS-485 Serial Communications Output that streams measured and derived data in ASCII format.

PERCENT (%) REJECTION
The Percent Rejection measurement feature compares feed water to the permeate (product) water to determine the percent of dissolved solids removed or rejected by a filtration system thereby quantifying the effectiveness of water filtration systems.

  Conductivity TDS Resistivity Salinity pH ORP/mV IN Temperature
Ranges 0 µS – 200 mS 0 ppm – 200 ppt 10 KΩ – 40 MΩ 0 ppm – 200 ppt 0 – 14 pH ±2000 mV 0 – 250˚C
Accuracy ± 1% of reading ± 1% of reading ± 1% of reading ± 1% of reading ± 0.01 pH ± 2 mV ± 0.1˚C
Resolution 0.01 (<100 µS)

 

0.1 (<1000 µS)

1 (<10,000 µS)

0.01 (<100 mS)

0.1 (≤200 mS)

0.01 (<100 ppm)

 

0.1 (<1000 ppm)

1 (<10,000 ppm)

0.01 (<100 ppt)

0.1 (≤200 ppt)

0.01 (<100 kΩ)

 

0.1 (<1000 kΩ)

0.01 (<10 MΩ)

0.1 (≤40 MΩ)

0.001 (<10 ppt)

 

0.01 (<100 ppt)

0.1 (≤200 ppt)

0.01 pH 1 mV 0.1˚C/F
Auto

 

Temperature

Compensation

0-71˚C

 

32-160˚F

0-71˚C

 

32-160˚F

0-71˚C

 

32-160˚F

0-71˚C

 

32-160˚F

0-71˚C

 

32-160˚F

Adjustable Temperature

 

Compensation

0 – 10%/˚C 0 – 10%/˚C 0 – 10%/˚C 0 – 10%/˚C On/Off
Cond/TDS

 

Ratios

Preprogrammed

KCl, NaCl, 442™ KCl, NaCl, 442™ KCl, NaCl, 442™
Adjustable

 

Cond/TDS

Ratio Factor

0.20-7.99 0.20-7.99 0.20-7.99

900 Series Multi-Parameter Monitor/Controller Data Sheet

Housing img

TDS MONITOR BEFORE - AFTER

Item Part: TDS-BA-A
Suitable for in-line monitoring of conductivity on two points of the RO process: before and after membrane (inlet and outlet)
Electrodes included (5 m cable)
Easy installation and operation
Accurate and stable measurement
Automatic temperature compensation 0-99 ⁰C
Measuring Range:

  • Inlet: 0-200 µS/cm
  • Outlet: 0-20 µS/cm
  • Accuracy: 1.5 % (FS)

Stability: ± 2*10 -3 /24 h
Dimensions: 1.9” x 3.8” x 3.9” (HxWxD)
Hole size of meter on panel: 1.8” x 3.6”
Hole size of sensor: ½” pipe thread
Power: 110 V or 220 V, 50 Hz

Housing img

TDS MONITOR WITH ALARM

Item Part: TDS-IL-A
Conductivity Meter for in-line monitoring with high level alarm
Includes TDS sensor with 5 m cable
Features:

  • High limit alarm
  • Temperature measurement
  • Can switch µS/cm – ppm
  • Auto range conversion
  • Back-light LCD display
  • Conductivity Range: 0-19.99 µS/cm, 0-199.9 µS/cm and 0-1999 µS/cm

Temperature range: 0-50 ℃
Accuracy: 1.5% (FS)
Stability: ± 1.5*10 -3 /24 h
Automatic temperature compensation.
Dimensions: 1.9” x 3.8” x 3.9” (HxWxD)
Hole size of meter on panel: 1.8” x 3.6”
Power: 110 V or 220 V, 50 Hz

TDS METER

Housing img

ULTRAPEN TDS METER

Item Part: TDS-MYRON PT1
Handheld meter with pocket clip
Measures 4 parameters:

  • Conductivity
  • TDS
  • Salinity
  • Temperature
  • Accuracy: ±1 %

Automatic temperature compensation Autoranging
Waterproof
Power: N Type Battery (1), included
Dimension: 6.75” L x 0.625” D


DATA SHEET

Housing img

POCKET TDS METER

Item Part: TDS
Handheld TDS meter with pocket clip
Range: 0-2999 ppm
Accuracy: 1 ppm
Hold function keep measure even when tester is not in water
Automatic temperature compensation
Auto shut off (saves battery)
Back-light color indicator:
Green: ≤ 40 ppm
Red: > 40 ppm
Battery operated (3 V Lithium CR2032, included)
Dimension: 150 mm x 27 mm x 17 mm

Housing img

TDS METER BEFORE - AFTER

Item Part: TDS-BA
Measure and display TDS on two points of the system (usually before and after RO membrane)
Green/Red back-light to indicate removal rate
Optional monitoring or continuous mode
Range: 0-999 ppm
Sensitivity: 1 ppm
Dimension: 4” x 1.6”
Thread size: ¼”
Battery operated (3 V Lithium CR2032, included)
Includes Velcro and clips for mounting

Housing img

TDS MONITOR BEFORE - AFTER

Item Part: TDS-BA-A
Suitable for in-line monitoring of conductivity on two points of the RO process: before and after membrane (inlet and outlet)
Electrodes included (5 m cable)
Easy installation and operation
Accurate and stable measurement
Automatic temperature compensation 0-99 ⁰C
Measuring Range:

  • Inlet: 0-200 µS/cm
  • Outlet: 0-20 µS/cm
  • Accuracy: 1.5 % (FS)

Stability: ± 2*10 -3 /24 h
Dimensions: 1.9” x 3.8” x 3.9” (HxWxD)
Hole size of meter on panel: 1.8” x 3.6”
Hole size of sensor: ½” pipe thread
Power: 110 V or 220 V, 50 Hz