Testers For Water Testing - Monitors For Water Filtration - Controllers For Water Filtration
MYRON L COMPANY
STANDARD SOLUTIONS & BUFFERS
The table below shows the Conductivity/TDS Equivalents for various Myron L® Standard Solutions.
Application Bulletin
POOLMETER™
PoolMeter™ Specifications:
Ranges: | 0-5000 ppm Total Dissolved Solids (TDS) "T" 0-5000 ppm Sodium Chloride (NaCl) "N" |
Accuracy: | ±2% of full scale
±1% at calibration point |
Repeatability: | ±1% |
Temperature
Compensation: |
Automatic to 25°C/77°F for samples
between 10-71°C/50-160°F |
Electrodes (Built-in): | Never need replatinizing or replacement |
Cell Cup: | Chip and crack resistant polyethylene |
Calibration: | Built-in standardization "S" value.
Easy and fast with standard solutions. |
Circuitry: | Sealed against moisture |
Power: | One 9V battery supplied;
Battery Life: >2000 tests/1 year |
Dimensions: | 3.4 W x 4.5 D x 4.0 H in./
86 W x 114 D x 102 H mm |
Weight: | 1 lb./0,45 kg |
Data Sheet
DIALYSATE METERS™ SINGLE & DUAL RANGE
DIALYSATE METERS™ Specifications:
Ranges: | |
MODEL D-1 | 11-15 millimhos |
MODEL D-2 | 0-10 millimhos
0-20 millimhos |
Accuracy: | ± 2% of full scale
±1% at calibration point |
Repeatability: | ±1% |
Temperature Compensation: | Automatic to 25°C/77°F for samples 10-71°C/50-160°F |
Electrodes: | Never need replatinizing or replacement |
Calibration: | Easy and fast with Standard Solutions and finger adjustable internal trimmer |
Circuitry: | Solid state, sealed against moisture |
Power: | Two standard 9-volt batteries supplied |
Battery Life: | Approximately 1 year or 2,000 tests |
Case: | Heavy gauge, textured ABS |
Cell Cup: | Chip/crack resistant polyethylene |
Dimensions: | 3.4 W x 4.5 D x 4.0 H in./ 86 x 114 x 102 mm |
Weight: | 1 lb./450 grams |
Data Sheet
RO METERS™
RO Meters™ Technical Specifications:
Ranges: | |
RO-1
RO-1NC |
0-1250 ppm (0-250 blue, 250-500 orange, 500-1250 red)
0-1250 ppm (no color band) |
Accuracy: | ±2% of full scale |
Repeatability: | ±1% |
Temperature Compensation: | Automatic (to 25°C/77°F) for samples between 10-71°C/50-160°F |
Electrodes (built-in): | Never need replatinizing or replacement |
Cell Cup: | Chip and crack resistant polyethylene |
Recalibration: | Internal electronic standard quickly verifies on-site accuracy |
Circuitry: | Solid-state, sealed against moisture |
Power: | One 9V battery supplied; Battery Life: >2000 tests/1 year |
Dimensions: | 3.4 W x 4.5 D x 4.0 H in./ 86 W x 114 D x 102 H mm |
Weight: | 1 lb./0,45 kg |
Data Sheet
AGRI-METERS™
AGRI-METERS™ Specifications:
Conductivity Range: | 0-5 millimhos |
pH Range: | 2-12 pH (AG6/PH only) |
Accuracy: | pH: ±0.2 pH units Conductivity: ±2% of full scale |
Repeatability: | ±1% |
Temperature Compensation: | Automatic (to 25°C) for Conductivity samples between 50-160°F/10-71°C |
Electrodes (Built-in): | pH: KCI gel-filled; field replaceable Conductivity: Never need replatinizing or replacement |
Calibration: | Easy finger adjustment of pH Zero and Gain (slope) and Conductivity |
Circuitry: | Solid State sealed against moisture |
Power: | One 9-volt battery supplied |
Battery Life: | Approximately one year or 2,000 tests |
Case: | Heavy gauge textured ABS |
Cell Cup: | Chip/crack resistant polyethylene |
Dimensions: | 3.4 W x 4.5 D x 4.0 H in./86 x 114 x 102 mm |
Weight: | Less than 1 lb./0,45 kg |
Data Sheet
DS & PDS METERS™
DS/pDS Meters™ Specifications:
Ranges: Conductivity
pH |
1, 3, 4 or 5 depending on model, 2-12 pH (pDS Meters only)
(See meters table) |
Readout: | 2½ in. taut-band shock resistant meter |
Units of Measure* | Choice of parts per million (ppm) TDS or micromhos (µM)/microsiemens (µS) conductivity |
Accuracy: Conductivity
pH |
±2% full scale
±0.2 pH units |
Repeatability | ±1% |
Temperature Compensation |
Automatic (to 25°C/77ºF) for conductivity samples between 10-71°C/50-160°F |
Calibration
Controls |
Conductivity
pH Zero and pH Gain |
Electrodes (built-in) | Conductivity: Never need replatinizing pH: KCl gel-filled, field replaceable |
Cell Cup | Chip and crack resistant polyethylene |
Circuitry | Very stable; requires minimal recalibration |
Power | One 9 volt battery supplied;
Battery Life: >2000 tests/1 year |
Dimensions | 3.4 W x 4.5 D x 4.0 H in./
86 W x 114 D x 102 H mm |
Weight | 1 lb./0,45 kg |
*1 µM (micromho) = 1 µS (microsiemen)
DS Meters™:
Model | 512T4* | 512M5* | 512T5* | 512T10* | 532M1* | 532T1* | 532T2* | EP-10 | EP |
Range(s) | 0-2500 | 0-5000 | 0-5000 | 0-10,000 | 0-50
0-500 0-5000 |
0-50
0-500 0-5000 |
0-25
0-250 0-2500 |
0-10
0-100 0-1000 0-10000 |
0-0.5
0-5 0-50 0-500 0-5000 |
Units Measured | ppm** | µM | ppm | ppm** | µM | ppm | ppm | µM | µM, MΩ |
Recommended NIST Standard Solution Key |
F | G | G | O | B,D,G | B,D,G | A,C,F | K,M,O | B,D,G |
pDS Meters™:
Model | T6/PH* | T2/PH* | EP11/PH |
Range(s) | 2-12 pH
0-5000 |
2-12 pH
0-50 0-500 0-5000 |
2-12 pH
0-10 0-100 0-1000 0-10000 |
Units Measured | pH, ppm | pH, ppm | pH, µM |
Recommended NIST Standard Solution Key |
G | B,D,G | K,M,O |
Data Sheet
TECHPRO™ II (TP1, TPH1)
TechPro II™ Specifications:
Display: | 4 Digit Liquid Crystal Display |
Dimensions: | 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in |
Weight: | 320 g/11.2 oz. |
Case/Cell Material: | Valox |
Cond/TDS Cell Capacity: | 5 ml/0.2 oz. |
pH Sensor Well Capacity: | 1.2 ml/0.04 oz. |
Power: | 9V alkaline battery |
Battery Life: | >100 hours (5000 readings) |
Operating/Storage Temperature: | 0 – 55°C/32 – 132°F |
Protection Ratings: | IP67/NEMA 6 WATERPROOF |
TechPro II™ Parameters:
Ranges:
Model | Conductivity | TDS | pH | TC – 25°C/77°F |
TP1 | 0 – 9999 µS
10 – 20.00 mS |
0 – 9999 ppm
10 – 20.00 ppt |
— | 0 – 71°C
32 – 160°F |
TPH1 | 0 – 9999 µS
10 – 20.00 mS |
0 – 9999 ppm
10 – 20.00 ppt |
0 – 14 | 0 – 71°C
32 – 160°F |
Accuracy:
Model | Conductivity/TDS | pH | Temperature Reading |
TP1 | ±1% of reading | — | ±0.1°C/F |
TPH1 | ±1% of reading | ±0.02 pH | ±0.1°C/F |
Data Sheet
ULTRAPENX2™ PTBT6
ULTRAPEN™ PTBT6 Specifications:
System Requirements: | Myron L® Company PTBTX2TM App: Apple iOS 10.0 or later; Android OS 7.0 or later. |
Specifications | Nitrate as Nitrogen NO3–N | Nitrate NO3– | Temperature |
Ranges | 1-1400 ppm | 4.4-6200 ppm | 0 – 71°C / 32 – 160°F |
Accuracy1 | ± 10% of the reading | ± 10% of the reading | ± 0.1°C |
Resolution | 0.1 ppm | 0.1 ppm | 0.1°C/F |
pH Range: | 3-11 pH |
Time to Reading Stabilization: | 10 – 180 seconds |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D |
Weight: | 54 g or 1.94 oz. |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | N type, Alkaline 1.5 V |
Calibration Standard Solutions: | 1, 10, 100, or 1000 ppm NO3–N |
Operating/Storage Temperature: | 0-40°C / 32-104°F2 |
Enclosure Ratings: | IP67 and NEMA 6 |
EN61236-1: 2006 – Annex A: 2008; Electrostatic discharge to case of instrument may cause PTBT6 to spontaneously power ON. In this case, the PTBT6 will power OFF after several seconds. |
Data Sheet
ULTRAPENX2™ PTBT5
ULTRAPENx2™ PTBT5 Specifications:
System Requirements: | Myron L® Company PTBTX2TM App: Apple iOS 10.0 or later; Android OS 7.0 or later. |
Specifications | DO Concentration | DO Saturation | Temperature |
Ranges | 0-20 ppm | 0-200% | 0 – 71°C / 32 – 160°F |
Accuracy1 | ± 0.2 ppm or ± 2% of the reading, whichever is greater (up to 40ºC) | 0.0% to ≤ 100.0%: ± 20 counts; >100%: ± 2% of the reading. | ± 0.1°C |
Resolution | 0.01 ppm | 0.1% | 0.1°C/F |
Altitude Adjustment: | -2,000 ft. to 15,000 ft. in increments of 100 ft. |
Salinity Adjustment: | 0 – 50 ppt in increments of 1 ppt |
Time to Reading Stabilization: | 10 – 180 seconds |
Calibration Methods: | 1 or 2 Point; 0 ppm DO Calibration Solution, Air or Water |
Operating/Storage Temperature: | 0 – 55°C / 32 – 131°F |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Temperature Compensation for Membrane Permeability: | Automatic |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D |
Weight: | 54 g or 1.94 oz. |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | N type, Alkaline 1.5 V |
Water Resistance: | IP67 and NEMA 6 |
EN61236-1: 2006 – Annex A: 2008; 1999/5/EC Annex III Electrostatic discharge to case of instrument may cause PT5 to spontaneously power ON. In this case, the PT5 will power OFF after several seconds. | |
WARNING! These products can expose you to chemicals including Di(2-ethylhexyl)phthalate (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. |
1Accuracy after Temperature Controlled, Full Calibration.
ULTRAPENx2™ PTBT5 Measurement Modes:
MODE | METHOD OF MEASUREMENT |
Hold | Displays real-time readings until stable or 3 minutes, whichever comes first, then displays final readings. |
LIVE | Displays real-time readings continuously for up to 5 minutes. |
ULTRAPENx2™ PTBT5 Parameter Modes:
MODE | PARAMETER MEASURED |
DO Default | Display alternates between DO Concentration in ppm, DO Saturation in % and Temperature. |
DO Concentration | Display alternates between DO Concentration in ppm and Temperature. |
DO Saturation | Display alternates between DO Saturation in % and Temperature. |
Data Sheet
ULTRAPENX2™ PTBT4
ULTRAPENx2™ PTBT4 Specifications:
System Requirements: | Myron L® Company PTBTX2TM App: Apple iOS 10.0 or later; Android OS 7.0 or later. |
FCE ™ Free Chlorine Range: | 0 – 10.0 ppm |
FCE ™ Free Chlorine Accuracy: | < 5.00 ppm: ± 0.3 ppm; ≥ 5.00 ppm: ± 0.5 ppm |
FCE ™ Free Chlorine Resolution: | 0.01 ppm |
Temperature Range: | 0 – 71°C / 32 – 160°F |
Temperature Accuracy: | ± 0.1ºC |
Temperature Resolution: | 0.1ºC / 0.1ºF |
Power Consumption: | Active Mode 30-140 mA Sleep Mode 2 µA |
Temperature Compensation: | pH: Automatic to 25ºC
ORP: Automatic In Calibration Mode From 15ºC to 30ºC |
Physical Dimensions: | 17,15 cm L x 1,59 cm D or 6.75 in. L x .625 in. D |
Weight: | 50.4 g / 1.78 oz. (without soaker cap and lanyard) |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | One N type, Alkaline, 1.5 V |
Calibration Standard Solutions: | PH4, PH7, PH10, ORP80, ORP260, ORP470 |
Operating/Storage Temperature: | 0 – 55ºC / 32 – 131ºF |
Enclosure Ratings: | IP67 and NEMA6 |
EN61236-1: 2006 – Annex A: 2008; | Electrostatic discharge to case of instrument may cause PTBT4 to spontaneously power ON. In this case, the PTBT4 will power OFF after several seconds. |
Data Sheet
ULTRAPENX2™ PTBT3
ULTRAPENx2™ PTBT3 Functions:
MODE | METHOD OF MEASUREMENT |
Hold | Once stabilized, the readings are captured then displayed. |
LIVE | Real-time readings are displayed continuously during measurement. |
ULTRAPENx2™ PTBT3 Specifications:
System Requirements: | Myron L® Company PTBTX2™ App: Apple iOS 10.0 or later; Android OS 7.0 or later. |
Measurement Range: | ORP: -1000 mV to +1000 mV; Temperature: 0 – 71ºC / 32 – 160ºF |
Accuracy: | ORP: ± 10 mV; Temperature: ± 0.1ºC |
Resolution: | ORP: 1 mV; Temperature: 0.1ºC / 0.1ºF |
Time to Reading Stabilization: | 10 – 45 Seconds |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Temperature Compensation: | Automatic In Calibration Mode From 15ºC to 30ºC |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D |
Weight: | 50.4 g / 1.78 oz |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | One N type, Alkaline 1.5 V |
Calibration Standard Solution: | ORP80, ORP260, ORP470 |
Operating/Storage Temperature: | 0 – 55ºC / 32 – 131ºF |
Water Resistance: | IP67 and NEMA 6 |
EN61236-1: 2006 – Annex A: 2008; | Electrostatic discharge to case of instrument may cause PTBT3 to spontaneously power on. In this case, the PTBT3 will power off after several seconds. |
FCC ID: T7VPAN17 | The Bluetooth transceiver device meets the requirements for modular transmitter
approval as detailed in FCC Public Notice DA00-1407. |
Canada (IC), license:
IC: 216Q-PAN17 |
The Bluetooth transceiver device meets the requirements for modular transmitter
approval as detailed in RSS-GEN. |
Data Sheet
ULTRAPENX2™ PTBT2
ULTRAPENx2™ PTBT2 Specifications:
System Requirements: | Myron L® Company PTBTX2™ App: Apple iOS 10.0 or later; Android OS 7.0 or later |
Measurement Range: | 0.00 – 14.00 pH; Temperature: 0°-71°C / 32-160°F |
Accuracy (After Wet Calibration): | ± 0.01 pH; Temperature: ± 0.1ºC |
Repeatability: | ± 0.01 pH; Temperature: ± 0.1ºC / ± 0.1ºF |
Resolution: | 0.01 pH; Temperature: 0.1ºC / ºF |
Time to Reading Stabilization: | 10 – 30 Seconds |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Temperature Compensation: | Automatic to 25ºC |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D |
Weight: | 54 g or 1.94 oz |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | One N type, Alkaline 1.5 V |
Calibration Standard Solution: | 4.0 pH, 7.0 pH, 10.0 pH |
Operating/Storage Temperature: | 0 – 55ºC / 32 – 131ºF |
Water Resistance: | IP67 and NEMA 6 |
EN61236-1: 2006 – Annex A: 2008; | Electrostatic discharge to case of instrument may cause PTBT2 to spontaneously
power on. In this case, the PTBT2 will power off after several seconds |
FCC ID: T7VPAN17 | The Bluetooth transceiver device meets the requirements for modular transmitter
approval as detailed in FCC Public Notice DA00-1407. |
Canada (IC), license:
IC: 216Q-PAN17 |
The Bluetooth transceiver device meets the requirements for modular transmitter
approval as detailed in RSS-GEN. |
Data Sheet
ULTRAPENX2™ PTBT1
ULTRAPENx2™ PTBT1 Specifications:
System Requirements: | Myron L® Company PTBTX2™ App: Apple iOS 10.0 or later; Android OS 7.0 or later. |
Measurement Range: | Conductivity & TDS: 1-9999 µS or ppm; Salinity: 0.0010-9.999 ppt;
Temperature: 0°-71°C / 32°-160°F |
Accuracy (After Wet Calibration): | ± 1% of Reading; Temperature: ± 0.1ºC |
Resolution: | Conductivity and TDS: 0.1 for 1.0 – 99.9 µS or ppm
1 for 100 – 9,999 µS or ppm Salinity: 0.0001 for 0.0010 – 0.0999 ppt 0.001 for 0.100 – 9.999 ppt Temperature: 0.1ºC orºF |
Repeatability: | <1000 µS or ppm ± 1 Count
≥ 1000 µS or ppm ± 0.3% of Reading |
Time to Reading Stabilization: | 10 – 20 seconds |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Temperature Compensation Method: | Automatic to 25ºC |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D |
Weight: | 55 g or 1.94 oz. |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | One N type, Alkaline 1.5 V |
Calibration Standard Solution: | KCl: 1800 µS for COND; 442™: 3000 ppm (2027 ppm NaCl) for TDS and Salinity |
Operating/Storage Temperature: | 0 – 55ºC or 32 – 131ºF |
Water Resistance: | IP67 and NEMA 6 |
EN61236-1: 2006 – Annex A: 2008; | Electrostatic discharge to the PTBT1 may cause it to spontaneously power on.
If this occurs, the PTBT1 will power off after several seconds. |
FCC ID: T7VPAN17 | The Bluetooth transceiver device meets the requirements for modular transmitter
approval as detailed in FCC Public Notice DA00-1407. |
Canada (IC), license:
IC: 216Q-PAN17 |
The Bluetooth transceiver device meets the requirements for modular transmitter
approval as detailed in RSS-GEN. |
ULTRAPENx2™ PTBT1 Functions:
MODE | PARAMETER | SOLUTION MODEL | UNITS |
Cond KCl | Conductivity | potassium chloride | microsiemens (µS) |
TDS 442 | Total Dissolved Solids (TDS) | Myron L® Company, 442 Natural Water™ Standard Solution | parts per million (ppm) |
TDS NaCl | Total Dissolved Solids (TDS) | sodium chloride | parts per million (ppm) |
SAL 442 | Salinity (SAL) | Myron L® Company, 442 Natural Water™ Standard Solution | parts per thousand (ppt) |
SAL NaCl | Salinity (SAL) | sodium chloride | parts per thousand (ppt) |
Data Sheet
ULTRAPEN™ PT6
ULTRAPEN™ PT6 Measurement Modes:
MODE | METHOD OF MEASUREMENT |
Hold | Displays real-time readings until the LED turns solid ON, then displays final readings. |
LIVE | Displays real-time readings continuously for up to 5 minutes. |
ULTRAPEN™ PT6 Parameter Modes:
MODE | PARAMETER MEASURED |
N | Display alternates between Nitrate as Nitrogen (NO3—N), and Temperature |
NO3 | Display alternates between Nitrate (NO3—), and Temperature |
mV | Display alternates between millivolt (mV), and Temperature |
ULTRAPEN™ PT6 Specifications:
Specifications | Nitrate as Nitrogen NO3—N | Nitrate NO3— | Temperature |
Ranges | 1-1400 ppm | 4.4-6200 ppm | 0 – 71°C / 32 – 160°F |
Accuracy1 | ± 10% of the reading | ± 10% of the reading | ± 0.1°C |
Resolution | 0.1 ppm | 0.1 ppm | 0.1°C/F |
pH Range: | 3-11 pH |
Time to Reading Stabilization: | 10 – 180 seconds |
Power Consumption: Active Mode: | 30 – 140 mA, Sleep Mode: 2 μA |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D |
Weight: | 54 g or 1.94 oz. |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | N type, Alkaline 1.5 V |
Calibration Standard Solutions: | 1, 10, 100, or 1000 ppm NO3—N |
Operating/Storage Temperature: | 0-40°C / 32-104°F2 |
Enclosure Ratings: | IP67 and NEMA 6 |
EN61236-1: 2006 – Annex A: 2008; Electrostatic discharge to case of instrument may cause PT6 to spontaneously power ON. In this case, the PT6 will power OFF after several seconds. |
Data Sheet
ULTRAPEN™ PT5
ULTRAPEN™ PT5 Measurement Modes:
MODE | METHOD OF MEASUREMENT |
Hold | Displays real-time readings until stable or 3 minutes, whichever comes first, then displays final readings. |
LIVE | Displays real-time readings continuously for up to 5 minutes. |
ULTRAPEN™ PT5 Parameter Modes:
MODE | PARAMETER MEASURED |
DO Default | Display alternates between DO Concentration in ppm, DO Saturation in % and Temperature. |
DO Concentration | Display alternates between DO Concentration in ppm and Temperature. |
DO Saturation | Display alternates between DO Saturation in % and Temperature. |
ULTRAPEN™ PT5 Specifications:
Specifications | DO Concentration | DO Saturation | Temperature |
Ranges | 0-20 ppm | 0-200% | 0 – 71°C / 32 – 160°F |
Accuracy1 | ± 0.2 ppm or ± 2% of the reading, whichever is greater (up to 40ºC) | 0.0% to ≤ 100.0%: ± 20 counts; >100%: ± 2% of the reading. | ± 0.1°C |
Resolution | 0.01 ppm | 0.1% | 0.1°C/F |
Altitude Adjustment: | -2,000 ft. to 15,000 ft. in increments of 100 ft. |
Salinity Adjustment: | 0 – 50 ppt in increments of 1 ppt |
Time to Reading Stabilization: | 10 – 180 seconds |
Calibration Methods: | 1 or 2 Point; 0 ppm DO Calibration Solution, Air or Water |
Operating/Storage Temperature: | 0 – 55°C / 32 – 131°F |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Temperature Compensation for Membrane Permeability: | Automatic |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D |
Weight: | 54 g or 1.94 oz. |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | N type, Alkaline 1.5 V |
Water Resistance: | IP67 and NEMA 6 |
EN61236-1: 2006 – Annex A: 2008; 1999/5/EC Annex III | Electrostatic discharge to case of instrument may cause PT5 to spontaneously power ON. In this case, the PT5 will power OFF after several seconds. |
Data Sheet
ULTRAPEN™ PT4
ULTRAPEN™ PT4 Measurement Modes:
MODE | METHOD OF MEASUREMENT |
Hold (default) | Once stabilized, the readings are captured then displayed. |
LIVE | Real-time readings are displayed continuously during measurement. |
ULTRAPEN™ PT4 Specifications:
FCE ™ Free Chlorine Range: | 0 – 10.0 ppm |
FCE ™ Free Chlorine Accuracy: | < 5.00 ppm: ± 0.3 ppm, ≥ 5.00 ppm: ± 0.5 ppm |
FCE ™ Free Chlorine Resolution: | 0.01 ppm |
Temperature Range: | 0 – 71°C / 32 – 160°F |
Temperature Accuracy: | ± 0.1ºC |
Temperature Resolution: | 0.1ºC / 0.1ºF |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Temperature Compensation: | pH : Automatic to 25°C ORP: Automatic in Calibration Mode from 15ºC to 30ºC |
Physical Dimensions: | 17.15 cm L x 1,59 cm D or 6.75 in. L x .625 in. D |
Weight: | 50.4 g / 1.78 oz. (without soaker cap and lanyard) |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | One N type, Alkaline, 1.5 V |
Calibration Standard Solutions: | PH4, PH7, PH10, ORP80, ORP260, ORP470 |
Operating/Storage Temperature: | 0 – 55ºC / 32 – 131ºF |
Enclosure Ratings: | IP67 and NEMA6 |
EN61236-1: 2006 – Annex A: 2008: | Electrostatic discharge to the PT4 may cause it to spontaneously turn on. If this occurs, the PT4 will turn off. |
Data Sheet
ULTRAPEN™ PT3
ULTRAPEN™ PT3 Functions:
MODE | METHOD OF MEASUREMENT |
Hold (default) | Once stabilized, the readings are captured then displayed. |
LIVE | Real-time readings are displayed continuously during measurement. |
* Temperature compensation in calibration mode: Temperature affects the reaction potentials for all chemicals differently. True ORP is the direct measurement of electron activity during an oxidation-reduction reaction, regardless of temperature. However, for maximum accuracy and ease of calibration, the Myron L® Company has developed three calibration standard solutions with known dissolved species. We derived the temperature compensation (from 15ºC to 30ºC) for those solutions, and embedded automatic temperature compensation into the calibration function of your PT3. Note: To verify calibration while in measurement mode, you must manually correct for any variation in temperature. Example: @25ºC, ORP2602OZ calibration solution will read 260mV, however @ 20.0ºC ORP2602OZ will read 265mV.
ULTRAPEN™ PT3 Specifications:
ORP Range: | -1000 mV to +1000 mV |
ORP Accuracy: | ± 10 mV |
ORP Resolution: | 1 mV ORP |
Temperature Range: | 0 – 71°C / 32 – 160°F |
Temperature Accuracy: | ± 0.1ºC |
Temperature Resolution: | 0.1ºC / 0.1ºF |
Time to Reading Stabilization: | 10 – 45 seconds |
Power Consumption: | Active Mode: 30 – 140 mA, Sleep Mode: 2 µA |
Temperature Compensation: | Automatic In Calibration Mode From 15ºC to 30ºC |
Physical Dimensions: | 17.15 cm L x 1.59 cm D or 6.75 in. L x 0.625 in. D |
Weight: | 50.4 g / 1.78 oz. (without soaker cap and lanyard) |
Case Material: | Anodized Aircraft Aluminum with Protective Coating |
Battery Type: | One N type, Alkaline, 1.5 V |
Calibration Standard Solutions: | ORP80, ORP260, ORP470 |
Operating/Storage Temperature: | 0 – 55ºC / 32 – 131ºF |
Enclosure Ratings: | IP67 and NEMA6 |
EN61236-1: 2006 – Annex A: 2008: | Electrostatic discharge to the PT3 may cause it to spontaneously turn on. If this occurs, the PT3 will turn off. |
Data Sheet
POOLPRO™ PS6FCᴱ & PS9TKB
POOLPRO™ Specifications:
Display: 4 Digit Liquid Crystal Display |
Dimensions: LxWxH 196 x 68 x 64 mm/ 7.7 x 2.7 x 2.5 in. |
Weight: 352 g/12.4 oz. |
Case/conductivity cell material: VALOX™ |
Cell capacities (w/o cell extender): pH/ORP: 1,2 mL/0.04 oz. Cond/TDS/MIN/SALT: 5 mL/0.2 oz. |
Power: 9V alkaline battery |
Battery life: >100 hours (5000 readings) |
Operating/storage temperature: 0 – 55°C/32 – 132°F |
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet) |
EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232 |
*™SABIC INNOVATIVE PLASTICS IP BV
Functional Specifications:
Conductivity | Ranges: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges |
Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1(<10 mS); 0.01(<100 mS); 0.1(<200 mS) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
TDS | Ranges: 0–9999 ppm; 10–200 ppt; in 5 autoranges |
Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
Mineral/Salt | Ranges: 0–200 ppt; in 5 autoranges |
Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
pH | Ranges: 0–14 pH |
Resolution: 0.01 pH | |
Accuracy**: ±0.01 pH | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
ORP | Ranges: ±999 mV |
Resolution: 1 mV | |
Accuracy**: ±1 mV | |
Free Chlorine FCE™ | Ranges: 0.00–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9 |
Resolution: 0.01 ppm | |
Accuracy**: <1.00ppm ±0.3ppm and ≥1.00ppm ±0.2ppm | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Alkalinity Titration | Ranges: 10-800 ppm |
Resolution: 0.1 ppm | |
Hardness Titration | Ranges: 0-1710 ppm / 0-100 grains |
Resolution: 0.1(<1000 ppm); 1(<1710 ppm); 0.1(<100 grains) | |
LSI Calculator | Ranges: -10 to +10 |
Resolution: 0.01 | |
Temperature | Ranges: 0–71°C / 32–160°F |
Resolution: 0.1°C/F | |
Accuracy: ±0.1°C |
*442 Natural Water Standard™ Myron L® Company
**EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
± 0.2 pH in the presence or RF fields ≥ 3 V/m.
± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).
Data Sheet
DIGITAL DIALYSATE METER™ D-4 & D-6
General Specifications:
Display: 4 Digit LCD |
Dimensions (LxWxH): 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in. |
Weight: 352 g/12.4 oz. |
Case Material: VALOX®* |
Cond/Res/TDS Cell Material: VALOX®* |
Cond/TDS Electrodes (4): 316 Stainless Steel |
Cond/Res/TDS Cell Capacity: 5 ml/0.2 oz. |
pH/ORP Sensor Well Capacity: 1,2 ml/0.04 oz. (D-6) |
Power: 9V Alkaline Battery |
Battery Life: >100 Hours/5000 Readings |
Operating/Storage Temperature: 0-55°C/32-131°F |
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet) |
Chemical Resistance: Resistant to hydrocarbons, dilute acids and bases, detergents, and aqueous salt solutions |
EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232 |
Flammability: PCB: UL94, V.0; Case: HB/1.47 or better |
* ® Sabic Innovative Plastics
Functional Specifications:
Conductivity | Range: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges |
Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1.0(<10 mS); 0.01(<100 mS); 0.1(<200 mS) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
TDS | Range: 0–9999 ppm; 10–200 ppt; in 5 autoranges |
Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1.0(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
Resistivity | Range: 10KΩ–30MΩ |
Resolution: 0.01(<100 KΩ); 0.1(<1000 KΩ); 0.1(>1 MΩ) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
pH (D-6) | Range: 0–14 pH |
Resolution: 0.01 pH | |
Accuracy**: ±0.01 pH | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
ORP (D-6) | Range: ±999 mV |
Resolution: 1mV | |
Accuracy**: ±1 mV | |
Free Chlorine FCE™ (D-6) | Range: 0.2–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9 |
Resolution: 0.01ppm | |
Accuracy**: <1.00 ppm ±0.3 ppm; ≥1.00 ppm ±0.2 ppm | |
Temperature | Range: 0–71°C / 32–160°F |
Resolution: 0.1°C/F | |
Accuracy: ±0.1°C |
*442 Natural Water Standard™ Myron L® Company
**EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
± 0.2 pH in the presence or RF fields ≥ 3 V/m.
± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).
Data Sheet
ULTRAMETER™ III 9PTKB
ULTRAMETER III 9P™ | Hard Carry Case Kit |
Display: 4 Digit LCD | Outer Material: ABS plastic |
Dimensions (LxWxH): 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in. | Inner Material: Foam |
Weight: 352 g/12.4 oz. | Dimensions: L x W x D: 13.6 x 10 x 5.4 in./346 x 254 x 137 mm |
Case/Cell Material: VALOX®* | * ® Sabic Innovative Plastics IP BV |
Cell Capacities (w/o cell extender): pH/ORP 1,2 mL/0.04 oz.
Cond/TDS/Res: 5 mL/0.2 oz. |
|
Power: 9v Alkaline Battery | |
Battery Life: 100 Hours/5000 Readings | |
Operating/Storage Temperature: 0-55°C/32-132°F | |
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet) | |
EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232 |
Functional Specifications:
Conductivity | Ranges: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges |
Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1(<10 mS); 0.01(<100 mS); 0.1(<200 mS) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99 | |
TDS | Ranges: 0–9999 ppm; 10–200 ppt; in 5 autoranges |
Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99 | |
Resistivity | Ranges: 10 KΩ–30 MΩ |
Resolution: 0.01(<100 KΩ); 0.1(<1000 KΩ); 0.1(>1 MΩ) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C | |
pH | Ranges: 0–14 pH |
Resolution: 0.01 pH | |
Accuracy**: ±0.01 pH | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
ORP | Ranges: ±999 mV |
Resolution: 1 mV | |
Accuracy**: ±1 mV | |
Free Chlorine FCE™ | Ranges: 0.00–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9 |
Resolution: 0.01 ppm | |
Accuracy**: <1.00ppm ±0.3ppm and ≥1.00ppm ±0.2ppm | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Alkalinity Titration | Ranges: 10-800 ppm |
Resolution: 0.1 ppm | |
Hardness Titration | Ranges: 0-1710 ppm / 0-100 grains |
Resolution: 0.1(<1000 ppm); 1(<1710 ppm); 0.1(<100 grains) | |
LSI Calculator | Ranges: -10 to +10 |
Resolution: 0.01 | |
Temperature | Ranges: 0–71°C / 32–160°F |
Resolution: 0.1°C/F | |
Accuracy: ±0.1°C |
*442 Natural Water Standard™ Myron L® Company
**EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
± 0.2 pH in the presence or RF fields ≥ 3 V/m.
± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).
Data Sheet
CONTROLSTIK II™ SYSTEM
Engineering Specifications:
Rinse water usage shall be minimized by means of automatic conductivity control systems. They shall consist of a temperature compensated conductivity sensor, corrosion resistant one-inch solenoid valve, and transformer box which safely reduces line power to the sensor. Enclosure shall be fiberglass with heavy rubber gasket and 316 stainless steel. Circuitry shall be solid-state, and unaffected by changes in voltage. Setpoint adjustment shall be on sensor to minimize tampering. Rinse tank controls shall be Myron L Model 597 or approved equal.
Transformer Box Specifications:
Input Power | Choice of 110 or 220 VAC, 50/60 Hz; |
Automatic voltage regulation insures operation of the systems from 105-125V or 210-250V respectively. | |
Output | 24 volts @ 600 mA AC |
Maximum Power Consumption | @ 117V: 12 watts (103 milliamps) |
Enclosure | IP65/NEMA 4X fiberglass case with heavy gasket and 316 stainless steel hardware. |
Lights | LEDs indicate POWER (red) and VALVE (yellow) |
Electrical Installation | Either HARDWIRE with 5/8 in. conduit; or PLUG-IN with 8 ft./2,4 meter, 18 ga. 3-conductor plug. |
(supplied with 110V systems only) | |
Mounting | Flange on enclosure for easy wall mounting |
Dimensions | 184 H x 197 W x 127 D mm/ 7.25 H x 7.75 W x 5 D in. |
Sensor Specifications:
Ranges | 5-500 micromhos (for high quality water) |
500-5000 micromhos (for normal tap water) | |
Power | 1 volt AC (from transformer box) |
On-Off Span | Approximately 5% of setpoint |
Temperature Compensation | Automatic to 25°C/77°F up to 82°C/180°F |
Materials | Epoxy and 316 stainless steel |
Cable | 10 ft./3 meter 22 ga., 4-conductor, vinyl jacketed |
Installation | Corrosion-proof ABS bracket supplied |
Dimensions | 304 L x 25 Dia. mm/12 L x 1 Dia. in. |
Solenoid Valve Specifications:
Size | 1 in. NPT normally closed; compatible with plastic or metal piping |
Power | 24 volts @ 200 mA AC |
(from transformer box) | |
Materials | Body: glass reinforced nylon |
Diaphragm: nylon reinforced BUNA N synthetic rubber | |
All exposed metal: stainless steel | |
Operating Pressure | 10-100 psi / 0,69-6,90 bar |
Miscellaneous | adjustable flow control |
manual override | |
anti-hammer closing | |
conduit connector |
Data Sheet
720 SERIES II PH / ORP MONITOR / CONTROLLERS
720 Series II Sensor Specifications:
- Temperature Compensation: Integral temperature sensor provides automatic TC to 25°C between 0 – 100°C/ 32 – 212°F.
- Pressure/Temperature Limits: P72S: Intermittent use up to 50 psi/690 kPa 100°C/212°F. High Temperature models available, see pH/ORP Sensor Selection Guide.
- Cable: 5 wire, 24 ga. shielded, 10 ft./3 meters standard. 25 and 100 ft./8 and 30 meter lengths available.
- Material: 1/2″ MNPT: CPVC body. 3/4″ MNPT: Ryton®* body.
- Dimensions: P72S typical: overall length 165 mm/6.5 in., body 127 mm/5 in., electrode length 19 mm/.75 in.
- *Ryton® PPS is a registered trademark of Chevron Phillips Chemical Company LLC
Functional Specifications:
Ranges | 0-14 pH or ±2000 mV ORP |
Display | Analog Models: 2.5 in./63 mm meter |
Digital Models: .5 in./13 mm 3½ Digit LCD | |
Digital Option: 3½ Digit Backlit | |
Linearity | Electronics: ±0.05% (±0.01 pH units/±1 mV of full scale) |
Resolution | Analog Meter: ±0.13 pH units/±40 mV |
Digital Display: ±0.01 pH units/±1 mV | |
Sensitivity | 0.05% of full scale (0.01 pH units/1.0 mV) |
Stability | ±0.05% of full scale (±0.01 pH units/±1.0 mV) |
Repeatability | ±0.05% of full scale (±0.01 pH units/±1.0 mV) |
Calibration Check | Built-in (7 and 0 pH / 0 and -2000 mV) |
Recorder Output | Isolated 0-10 VDC @ 5 mA max. (linear); standard all models 100Ω |
Output Impedance | 100Ω ±5% |
Sensor Inputs | 1; 3 input option available. |
(pH & ORP sensors may NOT be mixed.) | |
Control Function | Single Alarm/controller fully adjustable 0-100% of full scale |
Hysteresis: Adjustable from 0.3-3% of full scale | |
Indicators: Above (red) and below (green) set point LEDs (reversible) | |
Contact Rating: SPDT 10 amp @ 125 VAC, 30 VDC | |
Relay operates increasing or decreasing reading (selectable) | |
Second Alarm/controller, with above specifications – optional | |
Solid State Output | Powered; 24 VDC unregulated 30 mA max. |
Power | 115/230 VAC, 50/60 Hz, ±15% (user selectable) |
24 VAC optional | |
Maximum Power Consumption | @ 115V: 100 milliamps |
Dimensions | 152 H x 122 W x 96 D mm / 6 H x 4.8 W x 3.8 D in. |
Construction | Fully gasketed, heavy-duty ABS case; water resistant and corrosion proof IP65/NEMA 4X rated |
Ambient Temp Range | 0-60°C / 32-140°F |
Weight | 0,9 kg/2 lbs. |
Data Sheet
750 SERIES II RESISTIVITY MONITOR / CONTROLLERS
750 Series II Resistivity Sensor Specifications:
- Constant: 0.05
- Temperature Compensation: Two integral temperature sensors provide automatic TC to 25ºC.
- Pressure/Temp Limits: 100 psi/690 kPa @ 212ºF/100ºC.
- Bushing: Modular Polypropylene threaded 3/4" NPT. 1/2" PVDF or 316 stainless steel fittings (optional).
- Cable: Shielded 10 ft./3 meters standard; 25 and 100 ft./ 8 and 30 meter lengths available.
- Dimensions: Metal portion 30 L x 13 Dia. mm/ 1.2 L x .5 Dia. in.; overall length 91 mm/3.6 in.
Resistivity Sensor — CS10
All 750 Series II Resistivity models require a CS10 series sensor. This reliable sensor features two integral thermistors to ensure accurate and rapid automatic temperature compensation. The sturdy polypropylene standard bushing is modular for easy, inexpensive replacement. A PVDF or 316 stainless steel bushing can also be ordered. The metal portion is available in either 316 stainless steel (standard) or titanium.
Ranges | 7 ranges from 0-200K to 0-20MΩ |
See Price List for further details. | |
Display | Analog Models: 2.5 in./63 mm meter |
Digital Models: .5 in./13 mm 3½ Digit LCD | |
Digital Option: 3½ Digit Backlit | |
Accuracy | Analog Models: ± 2% of full scale |
Digital Models: ± 1% of full scale | |
Sensitivity | 0.05% of full scale |
Stability | 0.05% of full scale |
Repeatability | 0.1% of full scale |
Calibration Check | Built-in |
Recorder Output | 0-10 VDC @ 5 mA max. (linear); standard all models |
Sensor Inputs | 1 (3 input option available) |
Control Function | Single Alarm/controller fully adjustable 0-100% of full scale |
Hysteresis: Adjustable from 0.3-3% of full scale | |
Indicators: Above (green) and below (red) setpoint LEDs (reversible) | |
Contact Rating: SPDT 10 amp @ 250 VAC, 30 VDC. Relay operates decreasing or increasing reading (selectable). | |
Second Alarm/controller, with above specifications – optional | |
Solid State Output | Powered; 24 VDC unregulated 30 mA max. |
Power | 115/230 VAC, 50/60 Hz, ±15% (user selectable) |
24 VAC optional | |
Maximum Power Consumption | @ 115V: 100 milliamps |
Dimensions | 152 H x 122 W x 96 D mm / 6 H x 4.8 W x 3.8 D in. |
Construction | Fully gasketed heavy-duty ABS case; water resistant and corrosion proof IP65/NEMA 4X rated |
Ambient Temp Range | 0-60°C / 32-140°F |
Weight | 0,9 kg/2 lbs. |
Data Sheet
750 SERIES II CONDUCTIVITY / TDS MONITOR / CONTROLLERS
50 Series II Sensor Specifications:
- Temperature Compensation: Integral thermistors provide automatic TC to 25ºC between 0-100ºC/32-212ºF.
- Pressure /Temperature Limits: CS51: 100 psi / 690 kPa @ 100°C/212°F. 250 psig @ 205°C, Models CS40 and CS41 sensors available on special order.
- Bushing: Modular Polypropylene threaded 3/4" NPT. 1/2" PVDF or 316 stainless steel fittings available as option.
- Cable: Shielded 10 ft./3 meters standard 25 and 100 ft./ 8 and 30 meter lengths available. 100 ft./30 meter is maximum recommended.
- Dimensions: CS51: Metal portion 30 L x 13 Dia. mm/ 1.2 L x .5 Dia. in.
Sensors — CS51LC, CS51 and CS52
These reliable sensors feature an integral temperature sensor to ensure accurate and rapid automatic temperature compensation. The sturdy polypropylene bushing is modular for easy inexpensive replacement. Several alternatives for the metal portion of the sensor are available, depending on the demands of the application.
- CS51LC sensors (0.1 constant) are used for 5 and below.
- CS51 sensors (1.0 constant) are used between 0-10 and 0-20,000.
- CS52 sensors (10.0 constant) are used above 20,000.
- Low cost, low temperature, low pressure sensors available upon request. See 750II Sensor Selection Guide.
Ranges | 34 ranges from 0-1 ppm/μS (μM) to 0-200 ppt/mS (mM) |
See Price List for further details. | |
Display | Analog Models: 2.5 in./63 mm meter |
Digital Models: .5 in./13 mm 3½ Digit LCD | |
Digital Option: 3½ or 4½ Digit Backlit | |
Accuracy | Analog Models: ± 2% of full scale |
Digital Models: ± 1% of full scale | |
Sensitivity | 0.05% of full scale |
Stability | 0.05% of full scale |
Repeatability | 0.1% of full scale |
Calibration Check | Built-in |
Recorder Output | 0-10 VDC @ 5 mA max. (linear); standard all models |
Sensor Inputs | 1 (3 input option available) |
Control Function | Single Alarm/controller fully adjustable 0-100% of full scale |
Hysteresis: Adjustable from 0.3-3% of full scale | |
Indicators: Above (red) and below (green) setpoint LEDs (reversible) | |
Contact Rating: SPDT 10 amp @ 250 VAC, 30 VDC. Relay operates decreasing or increasing reading (selectable). | |
Second Alarm/controller, with above specifications – optional | |
Solid State Output | Powered; 24 VDC unregulated 30 mA max. |
Power | 115/230 VAC, 50/60 Hz, ±15% (user selectable) |
24 VAC optional | |
Maximum Power Consumption | @ 115V: 100 milliamps |
Dimensions | 152 H x 122 W x 96 D mm / 6 H x 4.8 W x 3.8 D in. |
Construction | Fully gasketed heavy-duty ABS case; water resistant and corrosion proof IP65/NEMA 4X rated |
Ambient Temp Range | 0-60°C / 32-140°F |
Weight | 0,9 kg/2 lbs. |
Data Sheet
ULTRAPEN PH / TEMPERATURE METER
Item Part: PH-MYRON PT2
Handheld meter with pocket clip
Measures 2 parameters:
- pH (0.00-14.00)
- Temperature (0–71 °C)
- Accuracy: ±0.01 pH
1, 2, 3 point calibration
Automatic temperature compensation
Waterproof
Power: N Type Battery (1), included
Dimension: 6.75” L x 0.625” D
DATA SHEET
MYRON 6PFC E ULTRAMETER II
Item Part: MYRON 6PIIFC
Measures 6 parameters on field:
- Conductivity
- Resistivity (10 KΩ–30 MΩ)
- TDS
- ORP (±999 mV)
- Free Chlorine (0.00–9.99 ppm)
- pH (0–14)
- Temperature (0–71 °C)
ORP mV to ppm free chlorine conversion pH/ORP Sensor protective cap
Four-digit display for full 9999 readings, with autoranging capability up to 200 mS/200 ppt
Memory for 100 readings with Date & Time Stamp
capable of wireless data transfer with bluDock™ option installed
Automatic temperature compensation
Auto shut-off
Waterproof
Power: 9 V battery (1)
Dimensions: 7.7” x 2.7” x 2.5”
DATA SHEET
MYRON 4PII ULTRAMETER
Item Part: MYRON 4PII
Measures 4 parameters on field:
- Conductivity
- Resistivity (10 KΩ–30 MΩ)
- TDS
- pH (0–14)
- Temperature (0–71 °C)
- Four-digit display for full 9999 readings, with autoranging capability up to 200 mS/200 ppt
Memory for 100 readings with Date & Time Stamp
Capable of wireless data transfer with bluDock™ option installed
Automatic temperature compensation
Auto shut-off
Waterproof
Power: 9 V battery (1)
Dimensions: 7.7” x 2.7” x 2.5”
DATA SHEET
CONTROLLERS
900 SERIES MULTI-PARAMETER MONITOR/CONTROLLER™
Outputs
4-20mA / 0-20mA Output
(Model 900M-3C only)
0-10V Recorder Output
The 900 Series 0-10V Recorder Output can be programmed to output 0-10 or 0-5 VDC and export signals from any input channel or derived value.
Relays and Alarms
The relays and alarms operate independently but may be programmed to work in conjunction. Relays and alarms may be set to trigger on measurement values rising above, falling below, In Window (within an upper and lower range of values), or Out Window (outside an upper and lower range of values) for any of the input channels or for derived % rejection.
RS-485 Output
(Model 900M-3C only)
The 900 Series features an RS-485 Serial Communications Output that streams measured and derived data in ASCII format.
PERCENT (%) REJECTION
The Percent Rejection measurement feature compares feed water to the permeate (product) water to determine the percent of dissolved solids removed or rejected by a filtration system thereby quantifying the effectiveness of water filtration systems.
Conductivity | TDS | Resistivity | Salinity | pH | ORP/mV IN | Temperature | |
Ranges | 0 µS – 200 mS | 0 ppm – 200 ppt | 10 KΩ – 40 MΩ | 0 ppm – 200 ppt | 0 – 14 pH | ±2000 mV | 0 – 250˚C |
Accuracy | ± 1% of reading | ± 1% of reading | ± 1% of reading | ± 1% of reading | ± 0.01 pH | ± 2 mV | ± 0.1˚C |
Resolution | 0.01 (<100 µS)
0.1 (<1000 µS) 1 (<10,000 µS) 0.01 (<100 mS) 0.1 (≤200 mS) |
0.01 (<100 ppm)
0.1 (<1000 ppm) 1 (<10,000 ppm) 0.01 (<100 ppt) 0.1 (≤200 ppt) |
0.01 (<100 kΩ)
0.1 (<1000 kΩ) 0.01 (<10 MΩ) 0.1 (≤40 MΩ) |
0.001 (<10 ppt)
0.01 (<100 ppt) 0.1 (≤200 ppt) |
0.01 pH | 1 mV | 0.1˚C/F |
Auto
Temperature Compensation |
0-71˚C
32-160˚F |
0-71˚C
32-160˚F |
0-71˚C
32-160˚F |
0-71˚C
32-160˚F |
0-71˚C
32-160˚F |
– | – |
Adjustable Temperature
Compensation |
0 – 10%/˚C | 0 – 10%/˚C | 0 – 10%/˚C | 0 – 10%/˚C | On/Off | – | – |
Cond/TDS
Ratios Preprogrammed |
KCl, NaCl, 442™ | KCl, NaCl, 442™ | – | KCl, NaCl, 442™ | – | – | – |
Adjustable
Cond/TDS Ratio Factor |
0.20-7.99 | 0.20-7.99 | – | 0.20-7.99 | – | – | – |
900 Series Multi-Parameter Monitor/Controller Data Sheet
TDS CONTROLLER
Item Part: TDS-IL
Conductivity Meter for in-line monitoring
Includes TDS sensor with 5 m cable
Features:
- 4-20 mA signal output
- Temperature measurement
- Can switch µS/cm – ppm
- Auto range conversion
- Back-light LCD display
- Conductivity Range: 0-19.99 µS/cm, 0-199.9 µS/cm and 0-1999 µS/cm
Temperature range: 0-50 ℃
Accuracy: 1.5% (FS)
Stability: ± 1.5*10 -3 /24 h
Automatic temperature compensation
Dimensions: 1.9” x 3.8” x 3.9” (HxWxD)
Hole size of meter on panel: 1.8” x 3.6”
Power: 110 V or 220 V, 50 Hz
PH CONTROLLER
Item Part: PH- CONT
Suitable for in-line monitoring of pH
Electrode included (5 m cable)
Back-light LCD display
High limit and low limit control
Automatically identifies pH buffer and three-point calibration
Measuring Range: 0-14
Resolution: 0.01
Accuracy: 0.05
Automatic temperature compensation 0-99 ⁰C
Stability: ≤ 0.05/24 h
Measuring distance: ≤ 20 m
Communication: RS485 output
4~20 mA current output
Dimensions: 3.8” x 3.8” x 5.1” (HxWxD)
Hole size on panel: 3.6” x 3.6”
Power: 110 V or 220 V, 50 Hz
ORP CONTROLLER
Item Part: ORP
Suitable for in-line monitoring of oxidation-reduction potential
Sensor Included (5 m cable)
Back-light LCD display
High limit and low limit control
Measuring Range: -1999 mV ~ +1999 mV
Resolution: ± 1 mV
Accuracy: ± 2 mV
Automatic temperature compensation 0-99⁰C
Stability: ≤ 2 mV/24h
Measuring distance: ≤ 20 m
Communication: RS485 output
4~20 mA current output
Dimensions: 3.8” x 3.8” x 5.1” (HxWxD)
Hole size on panel: 3.6” x 3.6”
Power: 110 V or 220 V, 50 Hz
RO CONTROLLER
Item Part: CONTR-M
RO controller with conductivity meter
Shows operation status of a reverse osmosis system through flow diagram
Combine PLC functions with TDS meter
Ready to be used with level control switch on storage tank
External lockout input
Remote operation capable
Programmable auto fast-flush cycle
TDS sensor with automatic temperature
compensation included (5 m cable)
Process controlled:
- Low inlet flow
- Low inlet pressure
- Inlet valve
- High pressure pump
- High conductivity level
- High level of water on tank
- Flush valve
- Measuring range: 0~200 µS/cm
Dimensions: 3.8” x 3.8” x 5.1” (HxWxD)
Hole size on panel: 3.6” x 3.6”
Power: 110 V or 220 V, 50 Hz
MONITORS
900 SERIES MULTI-PARAMETER MONITOR/CONTROLLER™
Outputs
4-20mA / 0-20mA Output
(Model 900M-3C only)
0-10V Recorder Output
The 900 Series 0-10V Recorder Output can be programmed to output 0-10 or 0-5 VDC and export signals from any input channel or derived value.
Relays and Alarms
The relays and alarms operate independently but may be programmed to work in conjunction. Relays and alarms may be set to trigger on measurement values rising above, falling below, In Window (within an upper and lower range of values), or Out Window (outside an upper and lower range of values) for any of the input channels or for derived % rejection.
RS-485 Output
(Model 900M-3C only)
The 900 Series features an RS-485 Serial Communications Output that streams measured and derived data in ASCII format.
PERCENT (%) REJECTION
The Percent Rejection measurement feature compares feed water to the permeate (product) water to determine the percent of dissolved solids removed or rejected by a filtration system thereby quantifying the effectiveness of water filtration systems.
Conductivity | TDS | Resistivity | Salinity | pH | ORP/mV IN | Temperature | |
Ranges | 0 µS – 200 mS | 0 ppm – 200 ppt | 10 KΩ – 40 MΩ | 0 ppm – 200 ppt | 0 – 14 pH | ±2000 mV | 0 – 250˚C |
Accuracy | ± 1% of reading | ± 1% of reading | ± 1% of reading | ± 1% of reading | ± 0.01 pH | ± 2 mV | ± 0.1˚C |
Resolution | 0.01 (<100 µS)
0.1 (<1000 µS) 1 (<10,000 µS) 0.01 (<100 mS) 0.1 (≤200 mS) |
0.01 (<100 ppm)
0.1 (<1000 ppm) 1 (<10,000 ppm) 0.01 (<100 ppt) 0.1 (≤200 ppt) |
0.01 (<100 kΩ)
0.1 (<1000 kΩ) 0.01 (<10 MΩ) 0.1 (≤40 MΩ) |
0.001 (<10 ppt)
0.01 (<100 ppt) 0.1 (≤200 ppt) |
0.01 pH | 1 mV | 0.1˚C/F |
Auto
Temperature Compensation |
0-71˚C
32-160˚F |
0-71˚C
32-160˚F |
0-71˚C
32-160˚F |
0-71˚C
32-160˚F |
0-71˚C
32-160˚F |
– | – |
Adjustable Temperature
Compensation |
0 – 10%/˚C | 0 – 10%/˚C | 0 – 10%/˚C | 0 – 10%/˚C | On/Off | – | – |
Cond/TDS
Ratios Preprogrammed |
KCl, NaCl, 442™ | KCl, NaCl, 442™ | – | KCl, NaCl, 442™ | – | – | – |
Adjustable
Cond/TDS Ratio Factor |
0.20-7.99 | 0.20-7.99 | – | 0.20-7.99 | – | – | – |
900 Series Multi-Parameter Monitor/Controller Data Sheet
TDS MONITOR BEFORE - AFTER
Item Part: TDS-BA-A
Suitable for in-line monitoring of conductivity on two points of the RO process: before and after membrane (inlet and outlet)
Electrodes included (5 m cable)
Easy installation and operation
Accurate and stable measurement
Automatic temperature compensation 0-99 ⁰C
Measuring Range:
- Inlet: 0-200 µS/cm
- Outlet: 0-20 µS/cm
- Accuracy: 1.5 % (FS)
Stability: ± 2*10 -3 /24 h
Dimensions: 1.9” x 3.8” x 3.9” (HxWxD)
Hole size of meter on panel: 1.8” x 3.6”
Hole size of sensor: ½” pipe thread
Power: 110 V or 220 V, 50 Hz
TDS MONITOR WITH ALARM
Item Part: TDS-IL-A
Conductivity Meter for in-line monitoring with high level alarm
Includes TDS sensor with 5 m cable
Features:
- High limit alarm
- Temperature measurement
- Can switch µS/cm – ppm
- Auto range conversion
- Back-light LCD display
- Conductivity Range: 0-19.99 µS/cm, 0-199.9 µS/cm and 0-1999 µS/cm
Temperature range: 0-50 ℃
Accuracy: 1.5% (FS)
Stability: ± 1.5*10 -3 /24 h
Automatic temperature compensation.
Dimensions: 1.9” x 3.8” x 3.9” (HxWxD)
Hole size of meter on panel: 1.8” x 3.6”
Power: 110 V or 220 V, 50 Hz
TDS METER
ULTRAPEN TDS METER
Item Part: TDS-MYRON PT1
Handheld meter with pocket clip
Measures 4 parameters:
- Conductivity
- TDS
- Salinity
- Temperature
- Accuracy: ±1 %
Automatic temperature compensation Autoranging
Waterproof
Power: N Type Battery (1), included
Dimension: 6.75” L x 0.625” D
DATA SHEET
POCKET TDS METER
Item Part: TDS
Handheld TDS meter with pocket clip
Range: 0-2999 ppm
Accuracy: 1 ppm
Hold function keep measure even when tester is not in water
Automatic temperature compensation
Auto shut off (saves battery)
Back-light color indicator:
Green: ≤ 40 ppm
Red: > 40 ppm
Battery operated (3 V Lithium CR2032, included)
Dimension: 150 mm x 27 mm x 17 mm
TDS METER BEFORE - AFTER
Item Part: TDS-BA
Measure and display TDS on two points of the system (usually before and after RO membrane)
Green/Red back-light to indicate removal rate
Optional monitoring or continuous mode
Range: 0-999 ppm
Sensitivity: 1 ppm
Dimension: 4” x 1.6”
Thread size: ¼”
Battery operated (3 V Lithium CR2032, included)
Includes Velcro and clips for mounting
TDS MONITOR BEFORE - AFTER
Item Part: TDS-BA-A
Suitable for in-line monitoring of conductivity on two points of the RO process: before and after membrane (inlet and outlet)
Electrodes included (5 m cable)
Easy installation and operation
Accurate and stable measurement
Automatic temperature compensation 0-99 ⁰C
Measuring Range:
- Inlet: 0-200 µS/cm
- Outlet: 0-20 µS/cm
- Accuracy: 1.5 % (FS)
Stability: ± 2*10 -3 /24 h
Dimensions: 1.9” x 3.8” x 3.9” (HxWxD)
Hole size of meter on panel: 1.8” x 3.6”
Hole size of sensor: ½” pipe thread
Power: 110 V or 220 V, 50 Hz